background image

- 9 - 

 

VG300**-OMH0006-A 

Countermeasures 

 

(5)

Reduce the supply oil to the amount at which the oil does not splash from the air exhaust port.

No.

Countermeasures

(1)

Adjust the pressure so that pilot pressure is within the specified range during operation.

(2)

- Replace the pilot valve assembly.

(3)

Adjust the pressure so that external pilot pressure is within the specified range during operation.

(4)

* If incorrect oil has been used for lubrication, remove the oil with air blow, and replace the valve with a new one. If a lubricant is
used in the system after the replacing the valve, use turbine oil Class 1 (with no additive) ISO VG32.

If there is a large amount of condensate or condensate cannot be removed completely, mount an auto drain or install a dryer
and replace the valve.

(6)

If air leakage is caused by foreign matter, remove foreign matter in the piping by air blow and replace the valve.

(7)

Repair or replace the actuators.

(8)

Stop the air and additionally tighten the bolt.

5. Foreign matter such as condensate or rubber entered.

6. Other than those specified, if precautions on the operation manual apply.

*If the product has failed, then please return the valve as it is.

If the countermeasures above are not effective, there may be a problem with the valve. Stop using the valve immediately.

If any of the examples below are applicable, there may be an internal problem in the valve. Stop using the valve immediately.

1. Oils other than specified were supplied.

2. Lubrication was stopped in the middle of lubrication. Or, lubrication was interrupted temporarily

3. Directly exposed to water

4. Severe impact was applied.

 
 
 
 
 
 
 
 
 
 
 

Содержание VGA342R Series

Страница 1: ...Doc No VG300 OMH0006 A PRODUCT NAME Air operated valve MODEL Series Product Number VGA342R Series...

Страница 2: ...ts Safety Instructions 2 3 Design Selection 4 Installation 4 Wiring 5 Lubrication 5 Air source 5 6 Operating Environment 6 Maintenance and Inspection 6 Specific Product Precautions 7 Trouble shooting...

Страница 3: ...n who has determined its compatibility with the product This person should also continuously review all specifications of the product referring to its latest catalog information with a view to giving...

Страница 4: ...d warranty and Disclaimer the product is 1 year in service or 1 5 years after the product is Also the product may have specified durability running distance or replacement parts Please consult your ne...

Страница 5: ...system having a vacuum the vacuum condition will not be maintained Use a valve designed for use under vacuum condition 8 Ventilation When using the valve in a closed control panel etc install ventilat...

Страница 6: ...ithin the system since the original lubricant applied within the product during manufacturing will be washed away please continue to supply lubrication to the system Without continued lubrication malf...

Страница 7: ...r shock 4 The valve should not be exposed to prolonged sunlight Use a protective cover 5 Remove any sources of excessive heat 6 If it is used in an environment where there is possible contact with oil...

Страница 8: ...to the value the same as the operating pressure Handling precautions 1 As the PE port is the exhaust port of the pilot valve do not plug or restrict it 2 The X port is the pressure supply port of the...

Страница 9: ...actuators such as cylinder 7 Sealing failure O ring is worn 6 Lodging of foreign matter For body ported type and N O specification from 1 P port Perform troubleshooting with higher possibilitybased o...

Страница 10: ...ely mount an auto drain or install a dryer and replace the valve 6 If air leakage is caused by foreign matter remove foreign matter in the piping by air blow and replace the valve 7 Repair or replace...

Страница 11: ...1993 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation...

Отзывы: