F.

 

Click 

Next

. The system scans the premise for 

wireless sensors that can be added, which 
must meet the following requirements:  

Not currently paired with another 
Touchscreen 

Is active. New sensors must be activated as 
follows; Turn the back cover counter-
clockwise to remove. Open the battery 
compartment. Removing the battery 
activation tab to power on the unit. 

Defaulted if previously paired. To default 
the sensor, refer to section 9 defaulting 
the alarm. 

Follow the system prompts to complete the 
add process. Trip the sensor by pressing and 
holding down the Test Button on the front 
cover of the alarm for 10 seconds.  

 

G.

 

When all the sensors are found and paired, 
tap 

Done

. Any located sensors that were not 

paired are released by the Touchscreen and 
can be added later. The Wireless Sensors 
Located screen shows the number of wireless 
sensors found and paired. 

H.

 

Tap 

Next

. The Configure Wireless Sensors 

screen shows icons of the sensors that were 
found and paired. 

I.

 

Tap 

Next

. The Add Sensor/Zone Modify 

screen appears. 

J.

 

To modify a field on the Touchscreen, tap 
the field. Use the onscreen keyboard to 
enter changes. Tap 

Next

 to save changes. 

K.

 

When all sensors are configured properly, tap 

Return to Menu

 in the Configure Wireless 

Sensors screen. 

L.

 

If all sensors have not been configured, the 
Modify screen appears for each sensor to let 
you review its details. Change the details as 
needed or tap 

Next

 to cycle through all the 

sensors. The sensors are marked as 
configured. 

7   

Mounting the Sensor 

The following procedure describes how to mount 
the SMCSM10-Z. Add the SMCSM10-Z to the 
Touchscreen before physically mounting it in the 
desired location. 

A.

 

Test communications between the 
Touchscreen and the SMCSM10-Z before 
permanently mounting the SMCSM10-Z as 
follows: 

Hold the SMCSM10-Z where you plan to 
install it. 

Press the SMCSM10-Z 

Test

 button for 10-

to-15 seconds. The SMCSM10-Z sends a 
signal to the Touchscreen. 

At the Touchscreen, verify the signal was 
received. A message will appear in the 
upper right corner of the Touchscreen for 
5 seconds. If no signal is received relocate 
the SMCSM10-Z and retest. 

B.

 

Using two supplied screws and anchors, 
mount the base. 

C.

 

Attach the SMCSM10-Z to the mounting base 
as follows: 

Line up the raised alignment tab on the lip 
of the SMCSM10-Z with the arrow on the 
mounting base. 

Insert the SMCSM10-Z into the base and 
turn clockwise about 15 degrees until it 
snaps into place. 

Note:

 

The SMCSM10-Z cannot be attached to the 

mounting base if no batteries are installed. 

Содержание SMCSM10-Z

Страница 1: ...re installation Considerations Install the SMCSM10 Z in accordance with the National Fire Protection Association s NFPA Standard 72 Chapters 2 and 8 Depending on the application you may need to reference other chapters of NFPA 72 or NFPA 101 Choosing an Installation Location When choosing an installation location consider Use of structure and type of construction Contents you want to protect and t...

Страница 2: ...ers Near fresh air inlets or returns or very drafty areas Near heating air conditioning vents fans and fresh air intakes which can drive smoke away from the smoke alarm In dead air spaces at the top of peaked ceilings or in corners where walls and ceiling meet Dead air can prevent smoke from reaching a smoke alarm Within 10 feet 3 m of fluorescent light fixtures Not suitable for outdoor use WARNIN...

Страница 3: ...m the SMCSM10 Z to unsnap it and lift it off C If you are replacing batteries remove and dispose of the batteries appropriately Wait 30 seconds after removal before continuing to the next instruction D Observing proper polarity as indicated in the battery compartment insert two new 3V lithium batteries into the SMCSM10 Z battery compartment and replace the battery compartment cover Note Use two ne...

Страница 4: ...rd to enter changes Tap Next to save changes K When all sensors are configured properly tap Return to Menu in the Configure Wireless Sensors screen L If all sensors have not been configured the Modify screen appears for each sensor to let you review its details Change the details as needed or tap Next to cycle through all the sensors The sensors are marked as configured 7 Mounting the Sensor The f...

Страница 5: ...screen into test mode refer to the Touchscreen documentation Using Test Button A Press the SMCSM10 Z Test button for 10 to 15 seconds The SMCSM10 Z sends a signal to the Touchscreen B At the Touchscreen verify the signal was received A message will appear in the upper right corner of the Touchscreen for 5 seconds Using Alarm Test Mode A Be sure the SMCSM10 Z is operating normally B Set the Touchsc...

Страница 6: ...security zone containing the smoke alarm F At the Sensor Diagnostic screen verify the RF signal strength and other parameters 10 Defaulting the Alarm This step should only be performed by a qualified service technician A Remove the SMCSM10 Z from the mounting plate B Remove the two batteries C Remove the smoke alarm s top cover by releasing the plastic clips starting with the one in the battery we...

Страница 7: ...Sensor Zone The Premise Passphrase keyboard appears D Enter the Premise Passphrase and click Done The currently installed sensors security zones appear E Tap the zone you want to delete and follow the instructions on the Touchscreen to delete the SMCSM10 Z and security zone from the current system 14 Maintenance The SMCSM10 Z is designed for a long service life of 10 years Although the Touchscreen...

Страница 8: ...CSM10 Z chamber cover with a dry or damp water cloth as needed to keep it free from dust and dirt When necessary use the following procedure to clean the interior of the smoke chamber and replace the smoke chamber A Notify the Central Monitoring Station that the SMCSM10 Z is being tested Be sure the system is in Test mode with the Central Monitoring Station B Remove the SMCSM10 Z from its mounting...

Страница 9: ...uctions in Section 9 to test the SMCSM10 Z link with the Touchscreen Be sure the SMCSM10 Z is enrolled into the Touchscreen properly Check with your Cable Operator to make sure you are using an approved Touchscreen with compatible software Tamper condition does not restore Be sure the SMCSM10 Z is installed properly onto the mounting plate and the mounting plate has a magnet Be sure there are no t...

Страница 10: ...years typically Sensor Photoelectric Sensitivity 2 2 1 3 ft Drift Compensation Adj 0 5 ft max Heat Detection Fixed 135 F 5 F 57 2 C 2 8 C Heat Rate of Rise 15 F min 105 F 8 3 C min 40 6 C Audible Alarm 85 dBa 10 3M temporal 3 Low Battery Beep 1 every 45 seconds RF Wireless Frequency 2 4 GHz Weight w battery 0 20 lbs 0 09 kg Dimensions 5 6 x 2 4 14 2cm x 6 1cm Storage temperature 4 to 140 F 20 to 6...

Страница 11: ...d single station smoke alarms shall be installed in accordance with 7 6 2 10 of NFPA 101 outside every sleeping area in the immediate vicinity of the bedrooms and on all levels of the dwelling unit including basements 101 18 3 4 4 2 For exceptions refer to this section of NFPA 72 NFPA 72 8 1 4 1 4 2 Detection in Existing Apartment Buildings Approved single station smoke alarms shall be in stalled ...

Страница 12: ...arest air is usually near the floor If you have to go through a closed door carefully feel the door and door knob to see if undue heat is present If they seem cool brace your foot against the bottom of the door with your hip against the door and one hand against the top edge Open it slightly If a rush of hot air is felt slam the door quickly and latch it Unvented fire tends to build up considerabl...

Отзывы: