SMC-520 User Guide revision 1.3 SMC Ship Motion Control www.shipmotion.eu
2
SERIAL OUTPUT STRINGS
2.1.1
WIXDR
Example
$WIXDR,C,23.3,C,SMC,H,30.0,P,SMC*7B
Description
Form
Start Characters
$WIXDR
Transducer type (C)
C for temperature
Temperature (23.3)
Temperature in degrees, resolution 0.1°
Unit (C)
Unit for temperature, C=Celsius, F=Fahrenheit K=Kelvin
Name of transducer (SMC)
Default SMC, user configurable
Transducer type (H)
H for Humidity
Humidity (30.0)
Humidity in percent, resolution 0.1%
Unit (P)
Unit for humidity, P=Percent
Name of transducer (SMC)
Default SMC, user configurable
Checksum (*7B)
XOR checksum
Termination Characters
<CR><LF>
2.1.2
VAISALA HMP155 FORMAT
Example
RH= 7.8 %RH T= 23.1 'C
Description
Form
Transducer type (RH=)
RH=Relative Humidity
Humidity (7.8)
Humidity in percent, resolution 0.1%
Unit (%RH)
Unit for humidity, % Relative Humidity
Transducer type (T=)
T=Temperature
Temperature (23.1)
Temperature in degrees, resolution 0.1°
Unit ('C)
Unit for temperature, 'C=Celsius, 'F=Fahrenheit 'K=Kelvin
Termination Characters
<CR><LF>
Note:
The Vaisala HMP155 string is a position based string and not comma separated