- 13 -
SJ2000-OMM0001
Connector Assembly for Manifolds (for Junction Common)
Using the connector assembly (for junction common) for solenoid
valves installed in the manifold reduces the labor involved in
wiring work because common wiring for all solenoid valves is
integrated into a single wire.
Single solenoid Double solenoid,
3 position type, 4 position type
SJ3000-46-SC-
⃞
⃞
⃞
⃞
SJ3000-46-DC-
⃞
⃞
⃞
⃞
Lead wire length
For single solenoid: SJ3000-46-SC-
⃞
For double solenoid
For 3 position type : SJ3000-46-DC-
⃞
For 4 position type
How to Order
Indicate the part no. of the connector assembly for the manifold
and solenoid valve.
If the arrangement is complicated, please specify them by means
of the manifold specification sheet.
Note 1) Applications like connectors not wired to a valve is not possible.
Note 2) For the solenoid valve, please designate “No connector
(MOZ)” for the connector type.
Note 3) Connector assembly with lead wire for place where the
signals are transmitted to the common wiring. (Only the
valves of first station and/or last station of manifold are
compatible to connector with lead wire for common.)
(Example)
SS5J3-60-04U
------- 1set
∗
SJ3160N-5MOZ ----- 2sets
∗
SJ3260N-5MOZ ----- 2sets
∗
SJ3000-46-S --------- 1set (Connector assembly for single solenoid)
∗
SJ3000-46-SC ------- 1set (Connector assembly for single solenoid)
(for junction common)
∗
SJ3000-46-DC ------- 2sets (Connector assembly for double solenoid)
(for junction common)
The asterisk denotes the symbol for assembly. Prefix it to the
part nos. of the solenoid valve, etc.
Wiring Instructions for Connector Assembly (for Junction Common)
If only connector assembly (for junction common) is ordered,
please wire according to the instructions in the diagram below.
For details on socket mounting, please refer to “How to Use Plug
Connector” on the back page 12.
Wire connection instructions
1. Strip 6.5 to 7.5 mm from the tip of the lead wire.
2. Loosen the terminal screws (slotted screws) of the
power supply terminal connectors, plug the core
wire of the lead wire into the square holes of the
connector, tighten terminal screws at the proper
torque, and fasten them securely. (Gently pull the
lead wire and check that it is fastened.)
Precautions
- To remove the power supply terminal connector, pull it upward
as is. When mounting, push it in until it makes a snapping noise.
- When connecting wire, be careful because using lead wire that
is outside of compatible lead wire ranges, or that are tightened
to anything other than the proper torque, creates a risk of
defective contact and other problems.
Connector Assembly Part No.(for Junction Common)
How to Wire to PC Wiring System Compliant Power Supply Terminal
For junction common
Connector assembly
SJ3000-46-S
Connector assembly
(for junction common)
SJ3000-46-SC
Double solenoid
SJ3260N-5MOZ
Common wiring
SJ2000/3000 Series
Specific Product Precautions 6
Be sure to read before handling.
Common wiring
Socket
Insert the socket into the connector (N)
of the neighboring solenoid valve
Caution
Caution
Nil
300 mm
6
600 mm
10
1000 mm
15
1500 mm
20
2000 mm
25
2500 mm
30
3000 mm
50
5000 mm
Caution
Connector assembly
(for junction common)
SJ3000-46-DC
Single solenoid
SJ3160N-5MOZ