SMC Networks SJ2000 Series Скачать руководство пользователя страница 11

- 10 - 

 

SJ2000-OMM0001 

 

 
 

Changing the Connector Entry Direction 

 
 

To  change  the  connector’s  entry  direction,  set  the  switch  on  the 
top  of  the  connector  block  to  the  FREE  position,  before  turning 
the  connector.  Make  sure  to  set  the  switch  back  to  the  LOCK 
position  before  connecting  the  connector.  (When  the  switch  is 
difficult  to  slide,  move  the  connector  a  little  so  that  it  will  slide 
easier.) 
If  an  excessive  force  is  applied  on  the  connector  in  the  LOCK 
position,  the  connector  block  may  be  damaged.  Also,  using  in 
such a way that the connector floats in the FREE position, it may 
cause  the  lead  wire,  etc.  to  break.  Thus,  refrain  from  using  in 
these ways.

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

Manifold Mounting 

 
When attaching a manifold to a mounting surface, etc., with bolts, 
if  the  entire  bottom  surface  of  the  DIN  rail contacts the mounting 
surface  in  a  horizontal  mounting,  it  can  be  used  by  simply 
securing  both  ends  of  the  DIN  rail.  However,  for  any  other 
mounting  method  or  for  side  facing  and  rear  facing,  etc.,  secure 
the DIN rail with bolts at uniform intervals using the following as a 
guide: 2 to 5 stations at 2 locations, 6 to 10 stations at 3 locations, 
11 to 15 stations at 4 locations, 16 to 20 stations at 5 locations, 21 
to  25 stations  at  6  locations,  26  to  30  stations  at  7 locations  and 
more than 30 stations at 8 locations. 
In  addition,  even  in  the  case  of  a  horizontal  mounting,  if  the 
mounting  surface  is  subject  to  vibration,  etc.,  take  the  same 
measures indicated above. If secured at fewer than the specified 
number of locations, warping or twisting may occur in the DIN rail 
and manifold, causing trouble such as air leakage.

 

 
 
 
 
 
 
 
 
 

 
 

Fitting Assembly Replacement 

 

 

By replacing a valve’s fitting assembly, it is possible to change the 
port size of the 4(A), 2(B), 1(P), and 3/5(E) ports. When replacing 
it,  pull  out  the  fitting  assembly  after  removing  the  clip  with  a  flat 
heat  screwdriver,  etc.  To  mount  a  new  fitting  assembly,  insert  it 
into place and then fully reinsert the clip.

 

 
 
 
 
 
 
 
 
 
 
 
 

Note  1) To  change  the  port  size  of the  1(P),  3/5(E)  ports  into  the 

port sizes other than 

φ

8 (straight), specify the change by 

means of the manifold specification sheet. 

Note 2) Be careful to avoid damage or contamination to the O-rigs, 

as this can cause air leakage. 

Note  3)  When  removing  a  straight-type  fitting  assembly  from  a 

valve,  after  removing  the  clip,  attach  tubing  or  a  plug 
(KJP-02,  KQ2P-

⃞⃞) to the one-touch fitting, and pull it 

out  while  holding  the  tubing  or  plug.  If  it  is  pulled  out 

while  holding  the  release  button  of  the  fitting  assembly 

(resin part), the release button may be damaged. 

Note 4) Be sure to turn off the power and stop the supply of air 

before  disassembly.  Furthermore,  since  air  may  remain 

inside the actuator, piping and manifold, confirm that the 

air is completely exhausted before starting any work. 

Note  5)  While  inserting  a  tubing  into  an  elbow-type  fitting 

assembly, hold the main body of the assembly by hand. 

Failure to do so will exert an undue force on the valve or 

the fitting assembly, resulting in air leakage or damage. 

 

 

FREE 

LOCK 

 

SJ2000/3000  Series 

Specific  Product  Precautions  3 

Be sure to read before handling.   

Caution 

Caution 

Содержание SJ2000 Series

Страница 1: ...Doc No SJ2000 OMM0001 4 Port Solenoid Valve PRODUCT NAME SJ2000 3000 Series MODEL Series ...

Страница 2: ...s Safety Instructions 2 3 Precautions on Design Selection 4 5 Mounting 6 Piping 6 Wiring 6 Lubrication 6 Air Supply 7 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 to 13 Troubleshooting 14 Remedy 15 1 ...

Страница 3: ... its latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by...

Страница 4: ...placement parts Please consult your nearest sales branch For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product Prior to using SMC products please read and understa...

Страница 5: ...witch valve and a vacuum release valve If a non vacuum valve is installed in the middle of piping system having a vacuum the vacuum condition will not be maintained Use a valve designed for use under vacuum condition 10 Double solenoid type When using the double solenoid type for the first time actuators may travel in an unexpected direction depending on the switching position of the valve Impleme...

Страница 6: ...ossible to operate a valve in extreme temperature as low as 10o C Take appropriate measures to avoid freezing of drainage moisture etc in low temperature 6 Operation for air blowing When using a solenoid valve for air blowing use an external pilot type Use caution because the pressure drop caused by the air blowing can have an affect on the internal pilot type valve when the internal pilot type va...

Страница 7: ...proximately 1 4 turn As a reference value tightening torque is 0 4 to 0 5 N m 2 M5 After tightening the fitting by hand use a wrench to tighten the fitting an additional approximately 1 6 to 1 4 turn As a reference value tightening torque is 1 to 1 5 N m Note If tightened excessively the thread of the product may break or the gasket may deform If tightened insufficiently the thread of the product ...

Страница 8: ...e is direct contact with any of these 2 Do not use in an environment where flammable gas or explosive gas exists Usage may cause a fire or explosion The products do not have an explosion proof construction 3 Do not use in a place subject to heavy vibration and or shock 4 The valve should not be exposed to prolonged sunlight Use a protective cover 5 Remove any sources of excessive heat 6 If it is u...

Страница 9: ... connected to a single solenoid a dual 3 port valve or a 3 position valve will actuate Electric circuit diagram with positive common and light surge voltage suppressor Please connect it together with the polarity of the electric wiring of the manifold Valves with built in back pressure check valve is to protect the back pressure inside a valve For this reason use caution the valves with external p...

Страница 10: ...ng time is over 67 ms at 24 VDC When a power saving circuit is installed a diode to prevent reverse current is not available for 12 VDC spec Therefore use caution not to connect in reverse Be careful about the allowable voltage fluctuation since a voltage drop of about 0 5 V occurs due to a transistor Refer to the solenoid specifications of each valve for details Light Indication When equipped wit...

Страница 11: ...secured at fewer than the specified number of locations warping or twisting may occur in the DIN rail and manifold causing trouble such as air leakage Fitting Assembly Replacement By replacing a valve s fitting assembly it is possible to change the port size of the 4 A 2 B 1 P and 3 5 E ports When replacing it pull out the fitting assembly after removing the clip with a flat heat screwdriver etc T...

Страница 12: ... 1 The 4 A and 2 B ports use the KJ series so the tube can be removed by pressing on part of the release bush However for the 1 P and 3 5 E ports please press the release bush evenly as before Hold down part of the release bush with your finger or a similar tool as shown in the diagram and pull out in the direction by the arrow 2 Pull out the tube while holding down the release button so that it d...

Страница 13: ...oks open and they are locked automatically Next confirm that they are locked by pulling lightly on the lead wires Detaching To detach a socket from a connector pull out the lead wire while pressing the socket s hook with a stick having a thin tip approx 1 mm If the socket is used again spread the hook outward Plug connector lead wires have a standard length of 300 mm however the following lengths ...

Страница 14: ...solenoid valve etc Wiring Instructionsfor ConnectorAssembly for Junction Common If only connector assembly for junction common is ordered please wire according to the instructions in the diagram below For details on socket mounting please refer to How to Use Plug Connector on the back page 12 Wire connection instructions 1 Strip 6 5 to 7 5 mm from the tip of the lead wire 2 Loosen the terminal scr...

Страница 15: ...hifted Foreign matter caught in air seat of pilot valve Excessive amount of lubricant Higher voltage or wrong coil used Faulty wiring Poor contact at contactor wire or connection part Blown fuse or disconnection lead wire Poor seal on actuator cylinders etc side Faulty operation Pilot valve is not operated Though pilot valve does shift but main valve will not shift or will be sluggish Disconnectio...

Страница 16: ...n in this operation manual 3 Lubrication has been stopped intermediately or lubrication was suspended temporary 4 Water splashed directely 5 Strong impact was given 6 Alien substance such as drain and particle got into Drain or garbage invaded a valve Reduce the amount of lubricant to the degree that no oil splashes out of the air exhaust port E port Check voltage Replace valve pilot valve Protect...

Страница 17: ...otokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2008 SMC Corporation All Rights Reserved ...