L
Intermediate connector block assembly wiring example
L
Intermediate connector block assembly
L
Dimensions
For connector type
∗
When ordering with an intermediate connector block assembly installed
in the manifold, please order using the manifold specification sheet.
∗
Enables control of U side solenoid valves from the position where the intermediate
connector block assembly is installed
This connector block can be used by inserting it into the middle of the manifold.
This can be used, for example, when you wish to separate electrical control of valves in the same manifold, or when the number of control points is insufficient.
∗
This drawing shows the SJ3000-76-1A.
For flat ribbon cable (20 pins)
Connector block
Intermediate connector block
SOL.a
SOL.b
SOL.b SOL.a
20 19
8
6
4
7
5
3
2
1
SOL.a
SOL.b
SOL.b SOL.a
Double solenoid
(Station 4)
Double solenoid
(Station 3)
Double solenoid
(Station 2)
Double solenoid
(Station 1)
20 19
8
6
4
7
5
3
2
1
SOL.b SOL.a SOL.a SOL.b COM
Station 3
Station 4
SOL.b SOL.a SOL.a SOL.b COM
Station 1
Station 2
D side
U side
(SJ3000-76-1A)
5
3
/
1
2
4
D
2
4
D
D
2
4
D
2
4
15.5
FREE
LOCK
Applicable connector: 20-pin MIL type
with strain relief
(MIL-C-83503 compliant)
77
56.2
(20)
40
Intermediate connector block assembly
D side
U side
Series
Part no.
Note
SJ1000
SJ2000
SJ3000
SJ3000-76-1A
Flat ribbon cable (20 pins)
SJ3000-76-4A
Flat ribbon cable (26 pins)
87
SJ1000/2000/3000
Series