background image

PTE-300-V

Sheet  15

clockwise or anti-clockwise by one digit per step, according to the selected digit weight as
described previously.

This knob has no end and can be controlled at any speed. However if the control knob is turned
very fast the value will change at a maximum rate of 1 digit per second.

3.2.2. DISPLAYS AND OPTIC INDICATORS

3.2.2.1. Function MODE indicators

These two 3mm LED (red), one will always be lit and indicates the frequency mode
function that is actually selected.

They are associated with the press key MODE.

3.2.2.2. Ramp indicators

They are six 2 mm red LEDs, which indicate the situation of the ramp, in the
selection level and when it is active. They have 2 different function modes:

1. Permanently lit: this indicates the selection mode. In this situation the operator can select

new values, which will be shown in the frequency display. At this stage the selected values
are not in the output. The relationship between the LEDs and the parameters that can be
selected is as follows:

LED 1:

Indicates that the initial value of the first ramp can be selected. The value will be
shown in the display in Hz.

LED 6:

Indicates that the 

Start Chrono

 frequency value can be selected. The value will be

shown in the display in Hz.

LED 2:

Indicates that the frequency slope (rate of change) for the 1

st

 ramp, from the initial

to the final value can be selected. It is in Hz per second, (Hz/s). If 0 is selected the
equipment will go directly (step) to the final value.

LED 4:

Indicates that the final value of the 1

st

 ramp can be selected. The value will be

shown in the display in Hz.

LED 3:

It indicates that you can select the time duration in which the unit will remain in the
final value before starting the 2

nd

 ramp. This value will be shown in the display in

seconds (s). When 0 is selected the unit will maintain the final value indefinitely.

LED 5:

Indicates that the frequency slope (rate of change) for the 2

nd

 ramp, from the final

to the initial value can be selected. It is in Hz per second, (Hz/s). If 0 is selected
the equipment will go directly (step) to the initial.

These LEDs are associated with the press key SET.

Содержание PTE-300-V

Страница 1: ...INSTRUCTIONS MANUAL PTE 300 V THREE PHASE RELAY TEST SET EDITION 1 2 98 VERSION 1 10...

Страница 2: ...The priority of EUROSMC S A is to obtain the highest standards and quality in all our products serving to satisfy the expectations and necessities of our clients...

Страница 3: ...p parameters selection 14 3 2 1 3 Start the selected ramp 14 3 2 1 4 Regulation digit selection 14 3 2 1 5 Rotating control knob 14 3 2 2 DISPLAYS AND OPTIC INDICATORS 15 3 2 2 1 Function MODE indicat...

Страница 4: ...LIP FREQUENCY MODE F 30 4 1 3 DYNAMIC TEST SELECTING FREQUENCY RAMPS 30 4 1 4 DYNAMIC TEST START THE SELECTED RAMP 31 4 1 5 DYNAMIC TEST STEP TO 2 ND VALUE 31 4 1 6 TTL AUXILIARY OUTPUT CHARASTERISTIC...

Страница 5: ...TY 45 6 1 WARRANTY 45 6 2 AFTER SALES SUPPORT 45 6 3 OTHER EUROSMC PRODUCTS 45 FIGURES INDEX Figure 1 PTE 300 V Front Panel 8 Figure 2 Functional Modules 9 Figure 3 Front Module 10 Figure 4 Intelligen...

Страница 6: ...t PTE 300 V type BNC 4 Clips up to 50 A 2 reds and 2 blacks 4 Clips up to 10 A 2 reds and 2 blacks Replacement fuses 4 Fuses 5x20 100 mA fast 4 Fuses 5x20 400 mA 2 Fuses 5x20 500 mA 4 Fuses 5x20 630 m...

Страница 7: ...nding functions features that the PTE 300 V has a INTERNAL FREQUENCY GENERATOR Allows the user to work in any frequency between 40 and 300 Hz Also frequency ramps and steps can be easily preprogrammed...

Страница 8: ...contact type of 20 ms duration This can be used to start an external timer for timing measurements This signal is produced every time one of the power outputs changes its status or the Step key is ac...

Страница 9: ...network fault simulation In general all types of relays which require 3 voltages and 3 currents to function correctly c MISCELLANEOUS Due to its good characteristics of accuracy and stability the PTE...

Страница 10: ...to find new applications maintenance etc Briefly the unit has a user interface Front Panel that is communicated with the Power Amplifier through the microprocessors incorporated Of course a power supp...

Страница 11: ...he status of the signals applied in these taps Figure 3 Front Module 5 External Reference Taps contain the circuits to synchronize the power outputs to the phase and frequency signals connected to the...

Страница 12: ...chieving a high accuracy output Figure 4 Intelligent Generator Module As shown in the block drawing and in the front panel control functions a microprocessor is in charge of supervising all the functi...

Страница 13: ...SPLAY AND OPTIC INDICATORS this refers to the LED indicators and the selection displays CONNECTORS TAPS this refers to all taps input and output connectors etc which are contained in the PTE 300 V Thi...

Страница 14: ...to the right of the power supply switch It consists of 2 black taps This output is always active when the unit is switched on The taps have a distance of 19 mm which is the standard two pole plug siz...

Страница 15: ...ible to select a frequency value on which a pulse of 20 ms duration is produced at the Start Chrono output Hz 3 2 1 3 Start the selected ramp This key starts the ramp previously selected by pressing t...

Страница 16: ...arameters that can be selected is as follows LED 1 Indicates that the initial value of the first ramp can be selected The value will be shown in the display in Hz LED 6 Indicates that the Start Chrono...

Страница 17: ...alue and the units of the parameter selected which are located to the right of the display It can work in three different modes Hz frequency Hz s rate of change or slope S time duration in seconds Whe...

Страница 18: ...ls In each one of them can be selected the desired output level as well as the phase angle This section is situated in the central section of the unit and is clearly identified All the controls indica...

Страница 19: ...ing the digit to be adjusted The following resolutions can be obtained 1 digit 10 digits 100 digits When pressing this key for more than 2 seconds it will block the rotating pulse generator not allowi...

Страница 20: ...d again it will return to the 1 st value When this key and the similar key in the phase section are pressed at the same time for more than 2 seconds this function if both sections becomes synchronized...

Страница 21: ...he 2 nd Value Selection mode and that this value is shown in the display b LED indicator when 2 nd value is activated This is a 3 mm red LED that is situated over its corresponding press key It has tw...

Страница 22: ...or These three 3 mm LEDs red indicate the digit selection for regulation Only one will be lit indicating the digit above it to be regulated f Level selection display The display is made up of 4 digits...

Страница 23: ...ut off and the display will begin to flash for 5 seconds During this time it is possible to reset the output by pressing the ON OFF button 2 Th this LED indicates an internal thermal overload temperat...

Страница 24: ...by changing the digit to be adjusted The following resolutions can be obtained 1 digit 10 digits 100 digits When pressing this key for more than 2 seconds it will block the rotating pulse generator no...

Страница 25: ...you must repeat this process 3 3 2 2 OPTICAL INDICATORS AND DISPLAYS a LED indicator for 2 nd value selection This is a 3 mm red LED that is situated over the corresponding key When this LED is lit i...

Страница 26: ...trol Sections 3 4 1 CONTROL KEYS 3 4 1 1 Reset Pressing this key a reset in the unit is made selecting a three phase voltage system synchronized to the frequency generated by the IFG 50 or 60 Hz 3 4 1...

Страница 27: ...nt will be refereed to the 0 phase angle in PTE 300 V SLAVE of reference the connected equipment becomes the synchronizing reference for PTE 300 V The phase angles we select PTE 300 V will be refereed...

Страница 28: ...e the input signals to the unit Black tap 0 this is the common tap Red tap any DC or AC voltage between 5 and 250 V can be connected between the common tap 0 and this one The presence of voltage will...

Страница 29: ...r Start Chrono 3 4 3 3 RS 232 connector This communication connector serial port RS 232 is a CANON connector of 9 pins located in the upper left part of the unit Its pin out is as follows Where NC Not...

Страница 30: ...erator has the following values and readings 1 Initial frequency this is 50 00 or 60 00 Hz It depends on the frequency ordered when the unit was purchased 2 Function mode enters in the Normal Frequenc...

Страница 31: ...s the ramp initial value This selection can be made between 40 and 300 Hz 2 Press the key Set the LED indicator 2 slope 1 will light up and the display will change to the units Hz s Selection is made...

Страница 32: ...art the selected ramp the Ramp key should be pressed once and the ramp will follow the procedure previously programmed The LED indicators will begin to flash slowly indicating where the ramp is at eac...

Страница 33: ...e The active range is that which has its corresponding LED lit 4 2 4 REFERENCE SOURCE SELECTION When the unit is turned on it is synchronized to its own internal signal produced by the IFG This is ind...

Страница 34: ...0 187 6 25 V 0 33 A 0 0 01 A 0 01 0 33 A 8 A 0 0 24 A 0 24 8 A In this case if you increase the level with the output ON overload alarms may be produced due to transitories disconnecting the correspo...

Страница 35: ...n the output IMPORTANT When the unit is in this situation the displayed value cannot be changed even if the rotating knobs are turned When this key is pressed again the step will be the opposite which...

Страница 36: ...0 3 Selected value in channel 3 CH3 120 0 b AMERICAN SENSE The display shows in sexagesimal degrees 0 359 9 the phase angle between the OUTPUT and the selected reference source Freq EXT LINE and BUS...

Страница 37: ...1 st one At the same time there is a signal sent to Start Chrono output The LED will go off indicating the output is at the 1 st value NOTA You can select a 2 nd value even when the corresponding out...

Страница 38: ...MASTER SLAVE PRESS KEY The press key MASTER SLAVE is used to select the status of the unit in terms of REFERENCE and or CONTROL when it is connected with another equipment of the same model or other m...

Страница 39: ...ains pressed the selection cycle starts again To select one of the three modes just release the key when the desired is selected The sequence allows the following modes M LED indicator lit The unit is...

Страница 40: ...lue phase angle higher than the actual Signal Monitor active b Negative events Output OFF Step to 2 nd Value voltage current lower than the actual Step to 2 nd Value phase angle lower than the actual...

Страница 41: ...3 4 12VA low 1 8 2 8 3 8 12VA null 1 C 2 C 3 C No error 5V high 5V low 5V null No error 5V high 5V low 5V null No error 5V high 5V low 5V null No error 5V high 5V low 5V null No error 12V high 12V low...

Страница 42: ...hree output ranges generating voltages in the output to check the fuses Any errors in the bits previously mentioned are visualized in each channel with the following ABCD Level Display EFGH Phase Disp...

Страница 43: ...cy value to act as the limit of the above mentioned ramp between 40 and 300 Hz Programming of the time duration that the above mentioned frequency value remains before beginning the 2nd frequency ramp...

Страница 44: ...ution 0 001 0 01 0 1 A 0 8 000 A Regulation resolution 0 001 0 01 0 1 A Accuracy better than 1 of the selected value between 10 and 100 of the selected range Power 100 VA 1 minute and 50 VA continuous...

Страница 45: ...ource in the following ranges Voltage input between 5 and 300 V Current input between 0 1 and 25 A Frequency range between 40 and 70 Hz 5 4 SIGNAL MONITORS The unit has a signal monitor that can work...

Страница 46: ...not provoked by the following which may cause the warranty to be revoked Improper use of the product incorrect connections or operations not specified or explained in this Instruction Manual Any manip...

Отзывы: