Follow the instruction given below when designing, selection and handling your pressure sensor.

 The instructions on design and selection.

Installation, wiring, environment of use, adjustment, operation and maintenance described below must also be
followed.

 Product specifications

 

 Operate the pressure sensor with the specified voltage.

Operation with a voltage beyond specifications can cause malfunction or damage of the pressure sensor. Insufficient
supply voltage may not drive a load due to a voltage drop inside the pressure sensor. Verify the operating voltage of the
load before use.

 

 Do not operate beyond specification range.

Fire, malfunction or sensor damage can result.

 

 Do not exceed the specified maximum allowable load.

Otherwise it can cause damage or shorten the lifetime of the pressure sensor.

 

 Reserve a space for maintenance.

Remember to leave space for maintenance.

 

Product handling

 Installation

 

 Do no drop, hit or apply excessive shock (980 m/s

) to the pressure sensor.

Otherwise it can result in damage to the pressure sensor causing failure or malfunction.

 

 Do not pull lead wires or lift the body with lead wires. (Pulling strength less than 50N)

Hold the body when handing. Otherwise it can result in damage of the pressure sensor causing failure or malfunction.

 

 Follow the specified tightening torque

Excessive tightening torque can break the pressure sensor. Insufficient tightening torque can displace the pressure

sensor from the original position or loosen the mounting screws. The standard torque of the fittings are as shown in
below.

M3 : Tighten by hand, then turn it 1/4 revolutions with a wrench
M5 : Tighten by hand, then turn it 1/6 revolutions with a wrench
R

NPT1/8 : 7 to 9 N

m

 

 When piping, apply the wrench only to the metal option (attachment to be piped) integrated into the piping.

Applying the wrench in other position can break the pressure sensor.

 

 Blow off all the dust inside the pipes before piping the pressure sensor.

Otherwise it can cause damage or malfunction.

 

 When using tape sealant, leave a couple of screw threads unwrapped with tape sealant.

Otherwise it can cause damage or malfunction.

 

 Do not insert wires or other foreign matter into the pressure measurement port.

It can damage the pressure sensor causing failure or malfunction.

 

 Connect frame-ground terminal (FG terminal) to the ground when using a switching power supply.

 

 Insert a noise filter (power line noise filter, ferrite core, etc.) between the switching power supply and this

pressure sensor.

 Wiring

 

 Do not bend or apply tensile stress to lead wires repeatedly.

Wiring with repetitive bending stress or tensile stress can cause breakage of the lead wires. Replace the product when
damage to a lead wire is observed.

 

 Connect wires and cables correctly.

Miswiring can break the pressure sensor depending on a miswired circuit.

    Do not connect wires while the power is on.

Otherwise it can break the circuit inside the pressure sensor causing malfunction.

 

 Do not lay wires or cables with power cable or high-voltage cable in the same wiring route.

Otherwise the wires to the pressure sensor can be contaminated with noise or induced surge voltage from power lines
or high voltage lines causing malfunction. Lay the wires to the pressure sensor to a wire duct or in a protective tube
other than those for power lines or high voltage lines.

 

 Verify the insulation of wiring.

Poor insulation (interference with other circuit, poor insulation between terminals and etc.) can introduce excess voltage
or current to the pressure sensor causing damage.

- 4 -

PS##-OMG0004

Содержание PSE540 Series

Страница 1: ...Technical Specification Pressure Sensor PSE540 Series No PS OMG0004...

Страница 2: ...Contents Safety Model Indication Method Specification Full View with Dimensions Installation Examples of Internal Circuit and Wiring P2 P6 P7 P8 P9 P9 1 PS OMG0004...

Страница 3: ...etc Equipment or apparatus that conforms with those mentioned above n Contact our sales department when plans are made for the product to be used for the system 2 including equipment that concerns its...

Страница 4: ...k the c pressure sensor regularly to ensure proper operation Otherwise malfunction can cause an accident These instructions must be followed while in maintenance Turn off the power supply Stop the sup...

Страница 5: ...a wrench R NPT1 8 7 to 9 N m When piping apply the wrench only to the metal option attachment to be piped integrated into the piping Applying the wrench in other position can break the pressure senso...

Страница 6: ...remnant of wires from entering this product Take proper measures for the remnant not to enter the pressure sensor in order to prevent failure or malfunction Do not expose the pressure sensor to vibrat...

Страница 7: ...r Range 1 For vacuum 0 to 101kPa 3 For compound 100 to 100kPa Pipe Specification M3 M3 0 5 M5 M5 0 8 01 R1 8 with M5 female screw N01 NPT1 8 with M5 female screw R04 4 reducer R06 6 reducer IM5 M5 fem...

Страница 8: ...1minute Between lead block and case Insulation Resistance 50M or more 500VDC by Megameter Between lead block and case Vibration proof 10 to 500Hz smaller one 1 5mm or 98m s2 double amplitude each in d...

Страница 9: ...R06 PSE54 A M3 M5 PSE54 A IM5 PSE54 A IM5H A PSE54 A M5 PSE54 A M3 11 5 10 8 B 3 5 3 14 4 10 A PSE54 A R06 PSE54 A R04 6 4 B 20 18 B 10 A M5 0 8 01 R1 8 N01 NPT1 8 M3 M3 0 5 M5 M5 0 8 Width across fl...

Страница 10: ...nnection A part center is straightly pushed in by tools such as pliers Re use cannot be performed once it connects the connector for sensor connection completely When you fail in the connection mistak...

Отзывы: