The Pressure Sensor and this technical specification contain essential information for the protection of

users and others from possible injury and damage to property and to ensure correct handling.

  Please check that you fully understand the definition of the following messages (signs) before going on

to read the text, and always follow the instructions.

  Also read carefully the technical specification of relevant equipment or apparatus before use.

Indications

IMPORTANT MESSAGES

Read this manual and follow its instructions. Signal words such as WARNING,

CAUTION

 and

NOTE, will be followed by important safety information that must be carefully reviewed.

Indicates a potentially hazardous situation which could result in death
or serious injury if you do not follow instructions.

Indicates a potentially hazardous situation which if not avoided, may
result in minor injury or moderate injury.

     

NOTE

Gives you helpful information.

 Usage Restrictions

n

 

This product is designed for use in general equipment for factory automation. Never use this
product with equipment or apparatus that directly concerns human lives*

1

, or which

malfunction or failure can cause a huge loss.

*1: Equipment or apparatus that directly matters human lives means the following:

 

 Medical equipment such as life support systems or equipment used in operating rooms

 

 Compulsory equipment required by law such as the Fire Prevention Law, Construction Law and etc.

 

 Equipment or apparatus that conforms with those mentioned above.

n

 

Contact our sales department when plans are made for the product to be used for the system*

2

including equipment that concerns itself with the safety of persons or that seriously affects the
public. This usage needs special consideration*

3

.

*2: The system including equipment that concerns itself with the safety of persons or that seriously

affects the public means the following:

 

 Nuclear reactor control systems in nuclear power plants, safety protection systems or

    other systems important for safety in nuclear power facilities
 

 Driving control systems

 

of mass transportation systems, and flight control systems

 Equipment or apparatus that comes into contact with foods or beverages

      *3: Special consideration means discussing usage with our engineers to establish a safe system

          designed as fool-proof, fail-safe, redundant and etc.

n

 

Special consideration of safety or maintainability should be taken to prevent hazard or loss
caused by a failure or malfunction that is likely to occur in certain probability due to
environmental stress (deterioration).

L

 The special consideration means to fully review the equipment or apparatus in design stage

  and to establish a backup system in advance such as a redundant system or fail-safe system.
   

n

 

Use for an interlocking circuit

When using the pressure sensor as a sensor for interlock, adopt a double interlocking method
such as equipping the mechanical protection function in order to deal with a pressure sensor
failure.
Check the pressure sensor regularly to ensure proper operation.

Safety

- 2 -

PS##-OMG0004

Содержание PSE540 Series

Страница 1: ...Technical Specification Pressure Sensor PSE540 Series No PS OMG0004...

Страница 2: ...Contents Safety Model Indication Method Specification Full View with Dimensions Installation Examples of Internal Circuit and Wiring P2 P6 P7 P8 P9 P9 1 PS OMG0004...

Страница 3: ...etc Equipment or apparatus that conforms with those mentioned above n Contact our sales department when plans are made for the product to be used for the system 2 including equipment that concerns its...

Страница 4: ...k the c pressure sensor regularly to ensure proper operation Otherwise malfunction can cause an accident These instructions must be followed while in maintenance Turn off the power supply Stop the sup...

Страница 5: ...a wrench R NPT1 8 7 to 9 N m When piping apply the wrench only to the metal option attachment to be piped integrated into the piping Applying the wrench in other position can break the pressure senso...

Страница 6: ...remnant of wires from entering this product Take proper measures for the remnant not to enter the pressure sensor in order to prevent failure or malfunction Do not expose the pressure sensor to vibrat...

Страница 7: ...r Range 1 For vacuum 0 to 101kPa 3 For compound 100 to 100kPa Pipe Specification M3 M3 0 5 M5 M5 0 8 01 R1 8 with M5 female screw N01 NPT1 8 with M5 female screw R04 4 reducer R06 6 reducer IM5 M5 fem...

Страница 8: ...1minute Between lead block and case Insulation Resistance 50M or more 500VDC by Megameter Between lead block and case Vibration proof 10 to 500Hz smaller one 1 5mm or 98m s2 double amplitude each in d...

Страница 9: ...R06 PSE54 A M3 M5 PSE54 A IM5 PSE54 A IM5H A PSE54 A M5 PSE54 A M3 11 5 10 8 B 3 5 3 14 4 10 A PSE54 A R06 PSE54 A R04 6 4 B 20 18 B 10 A M5 0 8 01 R1 8 N01 NPT1 8 M3 M3 0 5 M5 M5 0 8 Width across fl...

Страница 10: ...nnection A part center is straightly pushed in by tools such as pliers Re use cannot be performed once it connects the connector for sensor connection completely When you fail in the connection mistak...