PSE300AC 

Series

Sensor Monitor

How to Order

PSE3

0AC

0

M

AB

Specifications

M12 Connector Type

Series

PSE300AC

Applicable SMC pressure sensor

PSE550

PSE531/PSE541

PSE561

PSE533/PSE543

PSE563/PSE573

PSE532

PSE564

PSE574

PSE530/PSE540

PSE560/PSE570

PSE575

PSE576

PSE577

Rated pressure range

0 to 2 kPa

0 to −101 kPa −100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa

0 to 2 MPa

0 to 5 MPa 0 to 10 MPa

Display/Set pressure range

−0.2 to 2.1 kPa 10 to −105 kPa −105 to 105 kPa −10 to 105 kPa −50 to 525 kPa −0.105 to 1.05 MPa −0.105 to 2.1 MPa −0.1 to 5.25 MPa −0.1 to 10.5 MPa

Display/Smallest settable increment

0.001 kPa

0.1 kPa

0.1 kPa

0.1 kPa

1 kPa

0.001 MPa

0.001 MPa

0.01 MPa

0.01 MPa

Electrical

Power supply voltage

12 to 24 VDC (

±

10%) with 10% voltage ripple or less

Current consumption

25 mA or less

Protection

Reverse connection protection

Accuracy

Display accuracy

±

0.5% F.S. 

±

Min. display unit (Ambient temperature of 25

°

C)

Repeatability

±

0.1% F.S. 

±

Min. display unit (Ambient temperature of 25

°

C)

Temperature characteristics

±

0.5% F.S. (Ambient temperature of 0 to 50

°

C, 25

°

C reference)

Switch 

output

Output type

Select from NPN or PNP open collector output.

Output mode

Select from hysteresis mode, window comparator mode, error output or switch output OFF.

Switch operation

Select from normal output or reverse output.

Max. load current

20 mA

Max. applied voltage (NPN only)

30 VDC

Internal voltage drop (Residual voltage)

1 V or less (with load current of 20 mA)

Delay time

 

*

1

1 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000, 5000 ms)

Hysteresis

Variable from 0

*

2

Protection

Over current protection

Sensor 

input

Input type

Voltage input: 1 to 5 VDC (Input impedance: 1 M

Ω

), Current input: 4 to 20 mA DC (Input impedance: 51 

Ω

)

Number of inputs

1 input

Connection method

M12-4 pin connector

Protection

Over voltage protection (up to a voltage of 26.4 VDC)

Display

Unit

 

*

3

MPa, kPa, Pa, kgf/cm

2

, bar, mbar, psi, inHg, mmHg, mmH

2

O

Display type

LCD

Number of screens

3-screen display (Main screen, Sub screen x 2)

Display color

1) Main screen: Red/Green, 2) Sub screen: Orange

Number of display digits

1) Main screen: 4-digit (7-segment), 2) Sub screen: 4-digit (Upper 1-digit 11-segment, 7-segment for other)

Indicator light

Lights up when switch output is turned ON. OUT1/OUT2: Orange

Digital filter

 

*

4

0, 10, 50, 100, 500, 1000, 5000 ms

Environment

Enclosure

IP65

Withstand voltage

1000 VAC for 1 minute between terminals and housing

Insulation resistance

50 M

Ω

 or more (500 VDC measured via megohmmeter) between terminals and housing

Operating temperature range

Operating: 0 to 50

°

C, Stored: −10 to 60

°

C (No freezing or condensation)

Operating humidity range

Operating/Stored: 35 to 85% RH (No condensation)

Standards

CE (EMC directive/RoHS directive)

Weight

55.4 g (without power supply or output lead wires)

Option (Power supply/Output lead wire)

Nil

Straight lead wire

L

Right angle lead wire

N

None

Unit specification

Nil

With unit selection function

*

1

M

SI unit only

*

2

P

With unit selection function (Initial value psi)

*

1

Input specification

0

Voltage input

1

Current input

Output specification

AB

2 output type (NPN or PNP switching type)

3-Screen Display

Options/Part Nos.

Description

Part no.

Note

Power 

supply/

output 

lead wire

ZS-31-B

Straight (5 m)  1 pc.

ZS-31-C

Right angle (5 m)  1 pc.

*

1   Under  the  New  Measurement  Act,  switches  with  a  unit 

selection function are no longer allowed for use in Japan.

*

2  Fixed unit: Pa, kPa, MPa

*

   For details on the lead wire with M12 connector and the assembly 

type connector for connecting to the sensor, refer to page 147.

*

1   Value without digital filter (at 0 ms)

*

2   If the applied pressure fluctuates around the set value, the hysteresis must be 

set to a value more than the amount of fluctuation, or chattering will occur.

*

3   This setting is only available for models with the unit selection function. 

Only MPa, kPa, or Pa is available for models without this function.

*

4   The response time indicates when the set value is 90% in relation to the step input.

5

B

Содержание PSE300AC

Страница 1: ...e ring FKM Pressure Sensor 3 Screen Display Sensor Monitor Remote Type 0 to 1 MPa 0 to 2 MPa 100 to 100 kPa 0 to 5 MPa 0 to 500 kPa 0 to 10 MPa Measured value Current pressure value Label Display item...

Страница 2: ...500 kPa PSE575 576 577 2 MPa 5 MPa 10 MPa For General Fluids Variations PSE56 Series Wetted parts Stainless steel 316L IP65 Oil free Single diaphragm construction Compact Pneumatic Pressure Sensor Lo...

Страница 3: ...et value Threshold value Reverse output Set value Threshold value Normal output Hi side Set value Threshold value Hysteresis Set hysteresis value Reverse output Lo side Set value Threshold value Rever...

Страница 4: ...Output Voltage output 1 to 5 V Current output 4 to 20 mA Impedance Output impedance Approx 1 k Maximum load impedance 500 or less at 24 VDC 100 or less at 12 VDC Nil Voltage output type 1 to 5 V 28 C...

Страница 5: ...l 304 Lead wire and M12 connector ZS 37 A 1 to 5 VDC 4 to 20 mA DC mm Part no D E F G H I ZS 31 X188 20 9 R1 8 Rc1 8 14 1 5 ZS 31 X175 29 13 R1 4 Rc1 4 17 1 6 Internal Circuits and Wiring Examples PSE...

Страница 6: ...voltage protection up to a voltage of 26 4 VDC Display Unit 3 MPa kPa Pa kgf cm2 bar mbar psi inHg mmHg mmH2O Display type LCD Number of screens 3 screen display Main screen Sub screen x 2 Display co...

Страница 7: ...ng Examples Setting of NPN open collector 2 outputs Pressure sensor 3 wire type Setting of NPN open collector 2 outputs Pressure sensor 2 wire type Setting of PNP open collector 2 outputs Pressure sen...

Страница 8: ...This eliminates wide variations of the indicated value Suction Verification Formula for Obtaining the Set Value This function constantly detects and updates the maximum minimum pressure when the powe...

Страница 9: ...ple setting mode or F1 A large bore cylinder or ejector consumes a large volume of air during operation and may experience a temporary drop in the supply pressure This function prevents the detection...

Страница 10: ...Straight 3 m ZS 37 B Right angle 3 m PCA 1557743 Assembly type connector ZS 31 C Right angle 5 m PLC PCA 1557743 Assembly type connector Lead wire and M12 connector Assembly type connector Set part no...

Страница 11: ...ironments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipp...

Отзывы: