Safety Instructions

Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.

Caution

SMC products are not intended for use as instruments for legal 

metrology.

Measurement  instruments  that  SMC  manufactures  or  sells  have  not  been 
qualified by type approval tests relevant to the metrology (measurement) laws 
of  each  country.  Therefore,  SMC  products  cannot  be  used  for  business  or 
certification ordained by the metrology (measurement) laws of each country.

Compliance Requirements

1) ISO 4414: Pneumatic fluid power – General rules relating to systems.

 

ISO 4413: Hydraulic fluid power – General rules relating to systems.

 

IEC 60204-1: Safety of machinery – Electrical equipment of machines.

 

(Part 1: General requirements)

 

ISO 10218-1: Manipulating industrial robots – Safety.

 

etc.

Caution

 indicates a hazard with a low level of risk which, 

if not avoided, could result in minor or moderate injury.

Caution:

Warning

 indicates a hazard with a medium level of risk which, 

if not avoided, could result in death or serious injury.

Warning:

Danger :

Danger

 indicates a hazard with a high level of risk which, 

if not avoided, will result in death or serious injury.

Warning

Caution

1. The  compatibility  of  the  product  is  the  responsibility  of  the 

person  who  designs  the  equipment  or  decides  its 

specifications.

Since the product specified here is used under various operating conditions, 
its compatibility with specific equipment must be decided by the person who 
designs  the  equipment  or  decides  its  specifications  based  on  necessary 
analysis and test results. The expected performance and safety assurance 
of the equipment will be the responsibility of the person who has determined 
its  compatibility  with  the  product.  This  person  should  also  continuously 
review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information,  with  a  view  to  giving  due  consideration  to  any  possibility  of 
equipment failure when configuring the equipment.

2. Only  personnel  with  appropriate  training  should  operate 

machinery and equipment.

The product specified here may become unsafe if handled incorrectly. The 
assembly, operation and maintenance of machines or equipment including 
our products must be performed by an operator who is appropriately trained 
and experienced.

3. Do not service or attempt to remove product and machinery/

equipment until safety is confirmed.

1. The inspection and maintenance of machinery/equipment should only be 

performed  after  measures  to  prevent  falling  or  runaway  of  the  driven 
objects have been confirmed. 

2. When the product is to be removed, confirm that the safety measures as 

mentioned above are implemented and the power from any appropriate 
source is cut, and read and understand the specific product precautions 
of all relevant products carefully.

3. Before  machinery/equipment  is  restarted,  take  measures  to  prevent 

unexpected operation and malfunction.  

4.  Contact  SMC  beforehand  and  take  special  consideration  of 

safety  measures  if  the  product  is  to  be  used  in  any  of  the 

following conditions. 

 

1. Conditions and environments outside of the given specifications, or use 

outdoors or in a place exposed to direct sunlight.

2. Installation on equipment in conjunction with atomic energy, railways, air 

navigation,  space,  shipping,  vehicles,  military,  medical  treatment, 
combustion  and  recreation,  or  equipment  in  contact  with  food  and 
beverages,  emergency  stop  circuits,  clutch  and  brake  circuits  in  press 
applications,  safety  equipment  or  other  applications  unsuitable  for  the 
standard specifications described in the product catalog. 

3. An application which could have negative effects on people, property, or 

animals requiring special safety analysis. 

4. Use in an interlock circuit, which requires the provision of double interlock 

for  possible  failure  by  using  a  mechanical  protective  function,  and 
periodical checks to confirm proper operation.

1. The product is provided for use in manufacturing industries.

The  product  herein  described  is  basically  provided  for  peaceful  use  in 
manufacturing industries. 
If  considering  using  the  product  in  other  industries,  consult  SMC  beforehand 
and exchange specifications or a contract if necessary. 
If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/

Compliance Requirements

The product used is subject to the following “Limited warranty and Disclaimer” and 
“Compliance Requirements”.
Read and accept them before using the product.

Limited warranty and Disclaimer

1. The warranty period of the product is 1 year in service or 1.5 years after 

the product is delivered, whichever is first.

2)

Also,  the  product  may  have  specified  durability,  running  distance  or 

replacement parts. Please consult your nearest sales branch.

2. For any failure or damage reported within the warranty period which is clearly our 

responsibility, a replacement product or necessary parts will be provided. 

This  limited  warranty  applies  only  to  our  product  independently,  and  not  to  any 

other damage incurred due to the failure of the product.

3. Prior to using SMC products, please read and understand the warranty terms 

and disclaimers noted in the specified catalog for the particular products.

2) Vacuum pads are excluded from this 1 year warranty.

A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. 
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad 
or failure due to the deterioration of rubber material are not covered by the limited warranty.

1. The  use  of  SMC  products  with  production  equipment  for  the  manufacture  of 

weapons of mass destruction (WMD) or any other weapon is strictly prohibited.

2. The  exports  of  SMC  products  or  technology  from  one  country  to  another  are 

governed by the relevant security laws and regulations of the countries involved 

in the transaction. Prior to the shipment of a SMC product to another country, 

assure that all local rules governing that export are known and followed.

These  safety  instructions  are  intended  to  prevent  hazardous  situations  and/or 

equipment damage. These instructions indicate the level of potential hazard with 

the labels of 

“Caution,”

 

“Warning”

 or 

“Danger

.

 They are all important notes for 

safety  and  must  be  followed  in  addition  to  International  Standards  (ISO/IEC)

1)

and other safety regulations.

Safety Instructions

Содержание PSE300AC

Страница 1: ...e ring FKM Pressure Sensor 3 Screen Display Sensor Monitor Remote Type 0 to 1 MPa 0 to 2 MPa 100 to 100 kPa 0 to 5 MPa 0 to 500 kPa 0 to 10 MPa Measured value Current pressure value Label Display item...

Страница 2: ...500 kPa PSE575 576 577 2 MPa 5 MPa 10 MPa For General Fluids Variations PSE56 Series Wetted parts Stainless steel 316L IP65 Oil free Single diaphragm construction Compact Pneumatic Pressure Sensor Lo...

Страница 3: ...et value Threshold value Reverse output Set value Threshold value Normal output Hi side Set value Threshold value Hysteresis Set hysteresis value Reverse output Lo side Set value Threshold value Rever...

Страница 4: ...Output Voltage output 1 to 5 V Current output 4 to 20 mA Impedance Output impedance Approx 1 k Maximum load impedance 500 or less at 24 VDC 100 or less at 12 VDC Nil Voltage output type 1 to 5 V 28 C...

Страница 5: ...l 304 Lead wire and M12 connector ZS 37 A 1 to 5 VDC 4 to 20 mA DC mm Part no D E F G H I ZS 31 X188 20 9 R1 8 Rc1 8 14 1 5 ZS 31 X175 29 13 R1 4 Rc1 4 17 1 6 Internal Circuits and Wiring Examples PSE...

Страница 6: ...voltage protection up to a voltage of 26 4 VDC Display Unit 3 MPa kPa Pa kgf cm2 bar mbar psi inHg mmHg mmH2O Display type LCD Number of screens 3 screen display Main screen Sub screen x 2 Display co...

Страница 7: ...ng Examples Setting of NPN open collector 2 outputs Pressure sensor 3 wire type Setting of NPN open collector 2 outputs Pressure sensor 2 wire type Setting of PNP open collector 2 outputs Pressure sen...

Страница 8: ...This eliminates wide variations of the indicated value Suction Verification Formula for Obtaining the Set Value This function constantly detects and updates the maximum minimum pressure when the powe...

Страница 9: ...ple setting mode or F1 A large bore cylinder or ejector consumes a large volume of air during operation and may experience a temporary drop in the supply pressure This function prevents the detection...

Страница 10: ...Straight 3 m ZS 37 B Right angle 3 m PCA 1557743 Assembly type connector ZS 31 C Right angle 5 m PLC PCA 1557743 Assembly type connector Lead wire and M12 connector Assembly type connector Set part no...

Страница 11: ...ironments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipp...