Wiring
Connections should only be made with the power supply turned off.
Use separate routes for the product wiring and any power or high voltage wiring.
Otherwise, malfunction may result due to noise.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode
power supply. When a switch-mode power supply is connected to the product, switching noise will be
superimposed and the product specification can no longer be met. This can be prevented by inserting a
noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the
product, or by using a series power supply instead of a switch-mode power supply.
●
Lead wire
Colour
Content
Black
Output for PF2D3
Brown
DC(+)
Blue
DC(-)
White
Analogue output
●
Connecting the wiring
Attaching the sensor connector to the lead wire (When the product connects to the PF2D2
)
Refer to the PF2D2
operation manual for details of the sensor connector pin numbers.
Strip the lead wire as shown. Do not cut the insulator.
Insert the corresponding wire colour into the pin number printed on the sensor connector, to the bottom,
then part A shown should be pressed in by hand to make temporary connection.
Part A should then be pressed in using a suitable tool, such as pliers.
: The connector cannot be re-used once it has been fully crimped.
In cases of connection failure such as incorrect order of wires or incomplete insertion, please use the new connector.
Содержание PF2D5 Series
Страница 21: ... 20 No PF OMG0006 F Characteristics data Flow characteristics pressure loss PF2D504 PF2D520 PF2D540 ...
Страница 23: ... 22 No PF OMG0006 F Dimensions in mm PF2D504 520 Model A PF2D504 9 53 PF2D520 12 7 ...
Страница 24: ... 23 No PF OMG0006 F PF2D540 ...
Страница 28: ... 27 No PF OMG0006 F PF2D520S 13 1S Tubing size A Tubing size B 4 33 mm 4 23 mm 5 39 mm 5 28 mm ...
Страница 29: ... 28 No PF OMG0006 F PF2D540S 19 1S Tubing size A Tubing size B 5 39 mm 5 39 mm 6 49 5 mm 6 49 mm ...