background image

 

 

 

Contents

 

 

Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -P.2 to 3 

 

Names and functions of parts - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.4 

 

Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -P.5 to 9 

 

Applicable Fluids - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.10 

 

Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.11 

 

Performance Curve - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.12 to 14 

 

Working Principle - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.15 

 

Maintenance Parts - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.15 

 

Piping and Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.16 

 

Dimensions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P.17 

 

 

 

 

 

Содержание PA5013

Страница 1: ...Doc no PAB OMY0027 PRODUCT NAME Process Pump MODEL Series Product Number PA5013...

Страница 2: ...ons P 2 to 3 Names and functions of parts P 4 Precautions P 5 to 9 Applicable Fluids P 10 Specifications P 11 Performance Curve P 12 to 14 Working Principle P 15 Maintenance Parts P 15 Piping and Oper...

Страница 3: ...nt failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The asse...

Страница 4: ...ts 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product...

Страница 5: ...ion piping Discharge port FLUID OUT Discharges the fluid taken in the pump Connect discharge piping Pilot air supply port P1 P2 Supplies air of set pressure Connect the air piping Foot Holds the produ...

Страница 6: ...uch as rubber hose or an accumulator to absorb the impact pressure 4 Liquid seals To ensure that fluid does not become sealed inside the process pump when stopping the pump relieve the discharge press...

Страница 7: ...ide the cracking pressure should be 0 02 MPa or less 2 Mounting Caution 1 Read the operation manual before mounting the product Read the operation manual carefully and understand the contents before m...

Страница 8: ...nt or as supply air testing under user s operating conditions is recommended 5 Operating environment Warning 1 Do not use in the following environments as this can cause failure 1 Locations with an at...

Страница 9: ...ice life of diaphragm and maintenance of consumable items If the operating cycle of the process pump exceeds the service life of diaphragm the diaphragm may be damaged due to deterioration If it is da...

Страница 10: ...ump Adjust the volume by operating the valve 6 When the discharge volume is large flow speed is high depending on the fluid type and operating conditions there will be cavitation leading to a poor ope...

Страница 11: ...ditions be sure to check it by means of experimentation 6 Compatibility is indicated for fluid temperatures specified for the respective products 60 C or less 7 These may be penetrated by fluids and t...

Страница 12: ...d areas PP Diaphragm PTFE Check valve PTFE PP PFA Liquid contact seals FFKM Fluid Refer to P 11 for applicable fluids Discharge rate 1 to 45 L min 1 to 50 L min Average discharge pressure 0 to 0 4 MPa...

Страница 13: ...ection procedures 1 First mark the intersection point for a discharge rate of 15 L min and a discharge pressure of 0 14 MPa 2 Find the pilot air pressure for the marked point In this case cycle 3 Hz t...

Страница 14: ...edures 1 Look up from the 4 Hz switching cycle to find the intersection with SUP 0 4 MPa 2 From the point just found draw a line to the Y axis to find the air consumption The result is approximately 2...

Страница 15: ...y is 100 mPa s and the discharge rate is 12 L min Since this is equivalent to 68 of the discharge rate for fresh water 12 L min 0 68 17 6 L min indicating that a discharge rate of 17 6 L min is requir...

Страница 16: ...d is performed by repeating this process with the control of an external solenoid valve 5 port valve Maintenance Parts It is not recommended to disassemble the process pump However if this is necessar...

Страница 17: ...on the discharge side is in an open state The pump performs suction with its own power even without priming Dry state suction lifting range up to 0 5m To restrict exhaust noise attach a silencer to th...

Страница 18: ...17 Dimensions...

Страница 19: ...da Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the...

Отзывы: