5
6
Calculation of Guide Load Factor
MY2H/M
1
100
200 300 400500
1000 1500
Piston speed
mm/s
Moment
N
⋅
m
20
1
2
3
4
5
10
30
50
40
60
MY2H/M
3
100
200 300 400500
1000 1500
Piston speed
mm/s
Moment
N
⋅
m
20
10
4
5
3
2
1
30
50
60
MY2H/M
2
100
200 300400 500
1000 1500
Piston speed
mm/s
Moment
N
⋅
m
10
1
20
30
50
60
5
4
3
2
0.2
Load mass
kg
50
60
40
30
20
10
5
4
3
2
1
100
200 300 400500
1000 1500
MY2H/
m
3
Piston speed
mm/s
Load Mass
Allowable Moment
Calculation of Load Factor for Dynamic Moment
Sum and Examination of Guide Load Factors
Equivalent load F
E
at impact
F
E
=
x
υ
a
x
g
x
m
=
x 300 x 9.8 x 7.525 = 309.7 (N)
M
1
E
:
Moment
M
1
E
max
(from 4 of graph MY2H/
M
1
where 1.4
υ
a
= 420 mm/s) = 42.9 (N·m)
M
1
E
=
x
F
E
x
Z
= x 309.7 x 38.1 x 10
-
3
= 3.93 (N·m)
Load factor
α
4
=
M
1
E
/
M
1
E
max
= 3.93/42.9 =
0.09
M
3
E
:
Moment
M
3
E
max
(from 5 of graph MY2H/
M
3
where 1.4
υ
a
= 420 mm/s) = 42.9 (N·m)
M
3
E
=
x
F
E
x
Y
= x 309.7 x 53.6 x 10
-
3
= 5.53 (N·m)
Load factor
α
5
=
M
3
E
/M
3
E
max
= 5.53/42.9 =
0.13
1
3
1
3
1
3
1
3
1.4
100
1.4
100
M
3
:
Moment
M
3
max
(from 3 of graph MY2H/
M
3
) = 60 (N·m)
M
3
=
m
3
x
g
x
X
= 7.525 x 9.8 x 140.1 x 10
-
3
= 10.33 (N·m)
Load factor
α
3
=
M
3
/
M
3
max
= 10.33/60 =
0.17
m
3
M
3
X
M
1
E
M
1
F
E
Z
MY2H40
MY2H25
MY2H16
MY2H40
MY2H25
MY2H16
MY2H40
MY2H25
MY2H16
MY2H40
MY2H25
MY2H16
M
3
F
E
Y
M
3
E
Σα
=
α
1
+
α
2
+
α
3
+
α
4
+
α
5
=
0.57
≤
1
The above calculation is within the allowable value and the selected model can be used.
Select a separate shock absorber.
In an actual calculation, when the sum of guide load factors
Σα
in the formula above is more than 1, consider decreas-
ing the speed, increasing the bore size, or changing the product series. Also, this calculation can be performed easily
with the “SMC Pneumatics CAD System”.
q
r
w
e
t
1097
Mechanically Jointed Rodless Cylinder
Series
MY2
MY3A
MY3B
MY1B
MY1M
MY1C
MY1H
MY1HT
MY1
W
MY2C
MY2H
MY3M
Individual
-X
D-
-X
Technical
data
P1057-P1120-E.qxd 08.10.3 2:27 PM Page 1097
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com