Back page 8
7. Do not fix and use the stroke adjusting unit
at an intermediate position (MY3B/MY3M).
If the stroke adjusting unit is fixed at an intermediate position,
an error may result depending on the collision energy. In that
case, the use of the holder mounting bracket for adjustment is
recommended. It is provided with the "-X416" or "-X417"
made-to-order specification.
(Refer to “MY3B/MY3M Stroke Adjusting Unit Tightening Tor-
que for Fixing Bolts.”)
If the stroke adjusting unit is used at an intermediate position,
the energy absorption capacity may be different. Refer to the
maximum absorbed energy on page 6 and 21 and operate
within the allowable absorption energy.
<Stroke adjustment of the adjustment bolt>
Loosen the lock nut for the adjustment bolt, adjust the stroke
on the head cover side with a hexagon wrench, and secure
with a lock nut.
<Stroke adjustment of the shock absorber: MY3B>
Loosen the two unit fixing bolts on the shock absorber side
and rotate the shock absorber for stroke adjustment. Tighten
the unit fixing bolts equally to secure the shock absorber. Use
caution not to overtighten the fixing bolts.
(Refer to “MY3B/MY3M Stroke Adjusting Unit Tightening Tor-
que for Fixing Bolts.”)
<Stroke adjustment of the shock absorber: MY3M>
Loosen the fixing bolt for the shock absorber. Rotate the shock
absorber and adjust it. Then, tighten the fixing bolt for the
shock absorber and secure the shock absorber. Additionally,
please be careful that the fixing bolt should not be tightened
excessively.
(Refer to “MY3M Shock Absorber Tightening Torque for Fixing
Bolts”.)
Handling
Bore size (mm)
16
25
40
63
Unit
Tightening torque
Unit: N
m
0.6
3.0
12
24
L
H
L
H
L
H
L
H
MY3B/MY3M Stroke Adjusting Unit
Tightening Torque for Fixing Bolts
Bore size (mm)
16
25
40
63
Unit
Tightening torque
Unit: N
m
0.6
1.5
3.0
5.0
L
H
L
H
L
H
L
H
MY3M Shock Absorber
Tightening Torque for Fixing Bolts
Caution
Series
MY3
Specific Product Precautions 3
Be sure to read this before handling.
For Actuator Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A).
MY3A3B.qxd 06.2.17 9:13 AM Page 51