Auto Switch Specifications
Type
Leakage current
Operating time
Impact resistance
Insulation resistance
Withstand voltage
Ambient temperature
Enclosure
Reed switch
None
1.2 ms
300 m/s
2
50 M
Ω
or more at 500 VDC Mega (between lead wire and case)
–10 to 60
°
C
IEC60529 standard IP67, waterproof (JIS C 0920)
Solid state switch
3-wire: 100
µ
A or less, 2-wire: 0.8 mA or less
1ms or less
1000 m/s
2
1000 VAC for 1 min. (between lead wire and case)
Lead Wire Length
Lead wire length indication
(Example)
0.5 m
3 m
5 m
L
Z
Nil
Lead wire length
L
D-M9P
Contact Protection Box/CD-P11, CD-P12
<
Applicable switch model
>
Contact Protection Box Specifications
Contact Protection Box Internal Circuit
Contact Protection Box Dimensions
Contact Protection Box/Connection
∗
Lead wire length
Switch connection side: 0.5 m
Load connection side: 0.5 m
D-A9 and D-A9
V
type switches do not have internal contact protection
circuits.
The operated load is an induction load.
The length of wiring to the load is 5 m or more.
The load voltage is 100 VAC.
A contact protection box should be used in any of the above situations.
Part no.
Load voltage
Max. load current
CD-P11
CD-P11
100 VAC
25 mA
200 VAC
12.5 mA
CD-P12
24 VDC
50 mA
CD-P12
Switch operation
position
(OFF)
Switch operation
position
(ON)
The hysteresis is the difference between the position of the auto switch as
it turns “on” and as it turns “off”. A part of operating range (one side)
includes this hysteresis.
Note) Hysteresis may fluctuate due to the operating environment.
Please contact SMC if hysteresis causes an operational problem.
Auto Switch Hysteresis
Note 1) Lead wire length “Z” (5 m applicable auto switches) is as follows.
Reed auto switch: Not available
Solid state switch: All types are produced upon receipt of order.
Note 2) For solid state switches with flexible wire specification, add “–61” at the
end of the lead wire length.
∗
Oil resistant flexible heavy-duty cord is used for D-M9
as standard. No need
to suffix -61 to the end of part number.
Flexible specification
(Example)
D-F9PWVL- 61
Reed switch: 2 mm or less
Solid state switch: 1 mm or less
Note)
Hysteresis
29
Auto Switch Specifications
Series
MY3
Note 1)
Surge absorber
Choke
coil
OUT Brown
OUT Blue
OUT (
+
)
Brown
OUT (
-
)
Blue
Choke coil
Zener diode
To connect a switch unit to a contact protection box, connect the lead wire
from the side of the contact protection box marked SWITCH to the lead
wire coming out of the switch unit. The switch unit should be kept as close
as possible to the contact protection box with a lead wire that is no more
than 1 meter in length.
MY3A3B.qxd 06.2.17 9:13 AM Page 37