Safety Instructions 

       

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage. 
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or 
“Danger.” 
They are all important notes for safety and must be followed in addition to International Standards 
(ISO/IEC)

*1)

 , and other safety regulations. 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems. 

 

  ISO 4413: Hydraulic fluid power -- General rules relating to systems. 

 

  IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements) 

 

  ISO 10218: Manipulating industrial robots -Safety.

                                                                                 

 

 

  etc. 

   

 

 
 

Caution 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications. 

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment. 

2. Only personnel with appropriate training should operate machinery and equipment. 

The product specified here may become unsafe if handled incorrectly. 
The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced. 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed. 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully. 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions. 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight. 
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog. 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis. 

4.Use  in  an  interlock  circuit,  which  requires  the  provision  of  double  interlock  for  possible  failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

Содержание MXZ12 Series

Страница 1: ...Doc no MX OMX0004 1 PRODUCT NAME Compact Cylinder with Linear Guide MODEL Series Product Number MXZ12 R L MXZ16 R L MXZ20 R L MXZ25 R L...

Страница 2: ...ions 2 Installation 2 1 Mounting 2 2 Air supply 2 3 Piping 2 4 Operating enviroment 2 5 Lubricating 2 6 Speed adjustment 2 7 Auto switch mounting 3 Maintenance 3 1 Precautions for maintenance 3 2 Repl...

Страница 3: ...t failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assem...

Страница 4: ...of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from th...

Страница 5: ...itch 2 wire 3wire Stroke length tolerance 1 1 3 to 0 mm when pressure is not applied 1 Stroke length tolerance does not include the amount of bumper change 2 Installation 2 1 Mounting 1 Mounting of bo...

Страница 6: ...m Min screw in depth mm Max screw in depth mm MXZ12 M3x0 5 0 63 5 6 MXZ16 M3x0 5 5 6 MXZ20 M3x0 5 5 5 6 3 MXZ25 M3x0 5 6 5 8 3 Caution 1 If bolts are too long they will come into contact with the brac...

Страница 7: ...5 Do not attach magnets to the rail and guide unit Since the rail and guide are made of a magnetic substance it could become magnetized if touched by a magnet etc This could cause auto switch malfunct...

Страница 8: ...ot be performed 3 For Stopper Caution 1 If a load is applied in the direction as shown on the right side an eccentric load will be applied to the guide In this case the product should not be used as a...

Страница 9: ...s If hands or fingers are caught it can lead to injury Caution 1 Do not disassemble and modify the product 2 If the cylinder is stopped at an intermediate position by external stopper position of the...

Страница 10: ...aftercooler air dryer or water droplet separator 3 Use the product within the specified fluid and ambient temperature range When operating at temperatures below 5oC water in the circuit may freeze and...

Страница 11: ...adiated heat generated by nearby heat sources When there is a heat source surrounding the product the radiated heat from the heat source may exceed the operating temperature range Protect it with a co...

Страница 12: ...nting position of the auto switch when the stroke end is detected For the setting of the auto switch make adjustment checking the actual operating condition Minimum Stroke for Auto Switch Mounting Aut...

Страница 13: ...witch before holding the product 2 When mounting an auto switch into the groove from the top When mounting an auto switch into the groove from the top after installation 3 When mounting the autoswitch...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...and electric power and exhaust all compressed air from the system Before restarting the equipment confirm that measures are taken to prevent sudden movement 3 2 Replenishment of grease Caution 1 Appl...

Страница 17: ...Base plate Stainless steel 9 Floating bushing A Stainless steel 10 Floating bushing B Stainless steel 11 Hexalobular socket head cap screw Chrome molybdenum steel Electroless nickel plating 12 Hexagon...

Страница 18: ...ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufactu...

Отзывы: