![SMC Networks MWB 100 Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/smc-networks/mwb-100-series/mwb-100-series_operation-manual_1299914009.webp)
- 9 -
2-2. Design
The compatibility of the product is the responsibility of the person who designs the equipment or decides its
specifications
!
W a r n i n g
- Refer to section 1-3 Precautions on model selection.
- Refer to the table below for the recommended rod dimensions.
Lock unit model
MWB
∗
32
MWB
∗
40
MWB
∗
50
MWB
∗
63
MWB
∗
80
MWB
∗
100
Applicable rod size *
Ø12
f8
Ø16
f8
Ø20
f8
Ø25
f8
Ø30
f8
Material
Carbon steel / Stainless
Surface treatment
Hard chrome alloy
10μm
Surface roughness
Max. roughness Rz1.6 or less
∗
If a larger diameter rod is used; it may lead to the breakage of the inner parts of the lock unit, mounting
failure of lock unit, operation failure or a decrease in lock holding force.
!
C a u t i o n
- The shape of the rod end to be inserted into the lock unit should be like those shown below so that
the lock unit seal and inner surfaces are not damaged.
(1) For male thread
(2) For female thread
Fig. 2 Rod end style
- Do not apply excessive lateral load or external force to the lock unit. They may break the lock unit.
- Do not use the product in applications where the rod rotates.
- Do not apply loads with impact, strong vibration or rotational forces while the lock mechanism is
activated.
External impact loads, strong vibrations or rotating forces may break or reduce the life of the lock unit.
- If the piping between the lock release port and the solenoid valve for locking is long or the piping
diameter is small, the stopping accuracy of the lock unit will be decreased.
- The rod will move suddenly if the lock unit is unlocked whilst the rod is under load or if the piston
is pressurised incorrectly. If the sudden movements frequently occur in the application, make
adjustment to the air circuit or control system to prevent short life or breakage of the lock unit.
- Do not operate the product outside of the specified rod speed.
- The base oil component of grease may seep out.
The base oil of grease in the lock unit may seep out from the holding plate or cap depending on the operating
conditions (ambient temperature of 40
o
C or more, pressurized condition, low frequency operation etc.). If the lock
unit is required for use in a clean room consult with SMC.
φD
φD
-
2
30°
面取部
φD
30°
φD
-
2
面取部
Chamfer
Chamfer
Содержание MWB 100 Series