1. Product Specifications
1-1. Lock unit specification
Lock unit model
MWB
∗
32-UT
MWB
∗
40-UT
MWB
∗
50-UT
MWB
∗
63-UT
MWB
∗
80-UT
MWB
∗
100-UT
Applicable rod size
mm *2
Ø12 f8
Ø16 f8
Ø20 f8
Ø20 f8
Ø25 f8
Ø30 f8
Locking operation type
Exhaust locking
Fluid
Air
Proof pressure
1.5MPa
Max. operating pressure
1.0MPa
Min. operating pressure
0.3MPa
Ambient and fluid temperature
-10
℃~
70
℃
(No freezing)
Operating fluid temperature
Lubrication
Not required (non-lube)
Rod speed mm/s
~
1000
Locking direction
Both directions
Holding force
(Maximum static load)(N) *1
630
980
1570
2450
3920
6080
Port size (Rc, NPT, G)
1/8
1/4
Mounting type
Basic type, axial foot type, flange type
*1 The holding force (max. static load) shows the maximum capability and does not show the normal holding capability.
Choose the cylinder based on the Selection graph (Page 6 and 7).
*2 Applicable rod size affects holding force. Ensure the rod used is the appropriate size as shown in the table above.
For the shape of the inserted rod, refer to Fig.2 Rod end style.
1-2. Stop accuracy
Lock unit model
MWB*32
MWB*40
MWB*50
MWB*63
MWB*80
MWB*100
Stop accuracy
±1.0mm
Conditions
(Used with
air cylinder)
・
Mounting orientation
・・・
Horizontal
・
Supply pressure
・・・
0.5MPa
・
Piston speed
・・・
300mm/s
・
Load condition
・・・
Upper limit of allowable value
Solenoid valve for lock
Mounted to the lock release port
Value shown is based on testing and the largest
value is quoted. (Test repeated 100 times)
!
W a r n i n g
・
Confirm the specifications.
This product is designed only for use in compressed air systems including vacuum. Do not operate at
pressures or temperatures outside of the specification, as this could cause damage or malfunction (Refer
to the specifications.)
Please contact SMC if using fluids other than compressed air (including vacuum) generated by air
compressor.
SMC does not guarantee against any damage if the product is used outside of the specification range.