Problem
Possible cause
Solution
Air leakage from the
table
Piston seal is worn out.
The seal parts need to be replaced. Contact
SMC.
The pinion gear is
broken.
Excessive kinetic energy was
applied to the rotary table.
Replace the rotary table with the new one.
After that, take the measures below.
・
Calculate the kinetic energy applied to the
rotary table and adjust the load and rotation
speed to make the value within the allowable
kinetic energy.
・
Mount an external stopper or shock absorber
to absorb the impact force
.
In this case, adjust so that the adjusting bolt
does not come into contact with the piston.
Set the rotation end with an external
stopper.
・
Do not apply external torque to the
product that exceeds the rated output.
Excessive external torque
was applied to the rotary
table.
Insufficient rotating
Angle.
The adjustment bolt for angle
adjustment is set at a smaller
angle than required.
Set the adjustment bolt correctly.
The auto switch will
not operate or
operates incorrectly.
The auto switch is mounted in
an inappropriate position.
Mount the auto switch in the correct position.
Effect of an external magnetic
field
Check that there is no strong magnetic field
present.
Trouble with the electrical
circuit
Check that there is no trouble with the
electrical circuit.
Trouble with the electrical
specification
Check there is no trouble with the electrical
specification.
- 43 -