-15-
No.LV50***-OMQ0004-B
Mounting and Installation
Installation
- Use the product within the specified operating pressure and temperature range.
Withstand pressure is 2.0MPa.
Withstand pressure depends on fluid temperature. Refer to the chart of the operating pressure range.
Mounting
- Never mount the switch in a place that will be used as a scaffold.
Mount the product so that the fluid flows in the direction indicated by the arrow on the side of the body.
Check the flow characteristics data for pressure loss and the straight inlet pipe length effect on accuracy
(page 63), to determine inlet piping requirements.
Do not sharply reduce the piping size.
- Piping port and the metal part of the body are grounded to DC(-)/blue line.
Do not use the power supply with positive ground.
- When multiple sensors are used in parallel, install them outside of the area shown below. (Uninstallable
area)
If the product is mounted in the area where installation is prohibited, the accuracy will decrease.
Uninstallable area
20mm
20mm
50mm
50mm