-23-
3.4 Parameter setting method
Initial setting for the basic parameters
Refer to the controller’s (LEC series) operation manual for detail.
As the “basic parameter” is unique data of each actuator, if an actuator other than the “electric actuator
/ guide rod slider” is used, refer to the operation manual of each actuator and the controller’s (LEC
series) operation manual for the basic parameter.
Note 1) Become effective after restarting the controller.
Note 2) The origin offset is used for the “return to origin”. / See <Origin offset> on page 25.
Description(Extract)
Initial input value
Input range
Controller ID
1
1 to 64
note1)
IO pattern
1: 64
-
Acceleration /
deceleration pattern
1: Trapezoid - motion
-
S-motion ratio
0
-
Stroke (+)
10000
10000
Stroke (-)
-10000
-10000
Maximum speed
Max. speed of each
product
Step data input limit:
Max. speed of each product
Maximum
acceleration /
deceleration
3000
to 3000
Default
In positioning
1
1 to product stroke
Origin offset
note2)
0.00
Origin direction: CCW
-10000 + ”
product stroke”
to 9999
Origin direction: CW
-9999 to +10000 - ”
product stroke”
Maximum pushing
force
-
-
Parameter protect
1: StepData
Changeable parameter
1: StepData, 2: Common
Enable switch
2: Disable
Select 1:Enable or 2:Disable when using a teaching
box
Model name
Part no. of each product
Only the English characters and numbers are
changeable.
W-area output end 1
0.00
-
W-area output end 2
0.00
-
Origin correction data
0.00
-