-26-
4. Wiring of cables / Common precautions
Warning
1. Adjusting, mounting or wiring change should never be done before disconnecting the power
supply to the product.
Electrical shock, malfunction and damage can result.
2. Do not disassemble the cables.
Use only specified cables.
3. Do not connect or disconnect the wires, cables and connectors when the power is turned on.
Caution
1. Wiring securely. Do not apply any voltage to the terminals other than those specified in the
Operation Manual.
2. Wire the connector securely.
3. Take appropriate measures against noise.
Noise in a signal line may cause malfunction. As a countermeasure separate the high voltage and low
voltage cables, and shorten the wiring lengths, etc.
4. Do not route input/output wires and cables together with power or high voltage cables.
The product can malfunction due to interference of noise and surge voltage from power and high
voltage cables to the signal line. Route the wires of the product separately from power or high voltage
cables.
5. Take care that actuator movement does not catch cables.
6.
Operate with all wires and cables secured. Avoid bending cables at sharp angles where they
enter the product.
7. Avoid twisting, folding, rotating or applying an external force to the cable.
Risk of electric shock, wire breakage, contact failure and loss of control of the product can happen.
8. Fix the motor cables protruding from the actuator in place before use.
The motor and lock cables are not robotic type cables and can be damaged when moved. Therefore
fix the cables and the connectors (part “A” in figure below) when set up.
9. Select “Robotic type cables” in case of inflecting actuator-cable repeatedly. And do not put
cables into a flexible moving tube with a radius smaller than the
specified value. (Min. 50mm).
Risk of electric shock, wire break, contact failure and loss of control for
the product can happen if “Standard cables” are used in case of inflecting
the cables repeatedly
10. Confirm proper wiring of the product.
Poor insulation (interference with other circuits, poor insulation between terminals and etc.) can apply
excessive voltage or current to the product causing damage.
11. The Speed / pushing force may vary, depending on the cable length, load and mounting
conditions etc.
If the cable length exceeds 5m, the speed/pushing force will be reduced 10% per 5m as the
maximum.( if cable length is 15m: 20% reduction as the maximum. )
[Transportation]
Caution
1. Do not carry or swing the product by the motor or the cables.
Connector
Motor cable
Lock cable
Actuator cable
Robotic type cable(Flexible type cable)