background image

 

LEF-TFN01

 

 

Installation and Maintenance Manual 

Electric Actuator / Slider Type 

Series LEF 

 

Applicable model number: 
LEFS*A-* 
LEFS*B-* 
LEFB*T-*

 

 
 

1 Safety Instructions 

This manual contains essential information for the protection of users and 
others from possible injury and/or equipment damage. 

• 

Read  this  manual  before  using  the  product  to  ensure  correct  handling 
and also read the manuals of related apparatus before use. 

• 

Keep this manual in a safe place for future reference. 

• 

These  instructions  indicate  the  level  of  potential  hazard  by  label  of 
“Caution”,  “Warning”  or  “Danger”,  followed  by  important  safety 
information which must be carefully followed. 

• 

To  ensure  safety  of  personnel  and  equipment  the  safety  instructions  in 
this  manual  and  the  product  catalogue  must  be  observed,  along  with 
other relevant safety practices. 

 

 

 

Caution 

Indicates a hazard with a low level of risk.  
Which  if  not  avoided,  could  result  in  minor  or 
moderate injury. 

 

 

Warning 

Indicates  a  hazard  with  a  medium  level  of  risk. 
Which  if  not  avoided,  could  result  in  death  or 
serious injury. 

 

 

Danger 

Indicates a hazard with a high level of risk. 
Which  if  not  avoided,  will  result  in  death  or 
serious injury. 

• 

Electromagnetic compatibility:  This product is class A equipment that is 
intended  for  use  in  an  industrial  environment.  There  may  be  potential 
difficulties 

in 

ensuring 

electromagnetic 

compatibility 

in 

other 

environments due to conducted as well as radiated disturbances.

 

 

Warning 

• 

Do  not  disassemble,  modify  (including  change  of  printed  circuit 
board) or repair the product. 

An injury or product failure may result. 

• 

Do not operate the product beyond the specification range. 

Fire, malfunction or equipment damage may result. 
Use the product only after confirming the specifications. 

• 

Do not use the product in the presence of flammable, explosive or 
corrosive gas. 

Fire, explosion or corrosion may result.  
This product does not have an explosion proof construction. 

• 

When using the product as part of an interlocking system: 

Provide a double interlocking system, for example a mechanical system. 
Check the product regularly to ensure correct operation. 

• 

Before performing maintenance, be sure of the following: 

Turn off the power supply. 

 

Caution 

• 

Always perform a system check after maintenance. 

Do not use the product if any error occurs.  
Safety cannot be assured if caused by un-intentional malfunction. 

• 

Provide  grounding  to  ensure  correct  operation  and  to  improve 
noise resistance of the product. 

This product should be individually grounded using a short cable. 

• 

Follow  the  instructions  given  below  when  handling  the  product. 

Failing to do so may result in product damage.

 

• 

Maintenance space should always be provided around the product. 

• 

Do not remove labels from the product. 

• 

Do not drop, hit or apply excessive shock to the product. 

• 

Unless stated otherwise, follow all specified tightening torques. 

• 

Do  not  bend,  apply  tensile  force,  or  apply  force  by  placing  heavy 
loads on the cables. 

1 Safety Instructions (continued) 

• 

Connect  wires  and  cables  correctly  and  do  not  connect  while  the 
power is turned on. 

• 

Do not route input/output wires and cables together with power or 
high-voltage cables. 

• 

Check the insulation of wires and cables. 

• 

Take  appropriate  measures  against  noise,  such  as  noise  filters, 
when the product is incorporated into other equipment or devices. 

• 

Take sufficient shielding measures when the product is to be used 
in the following conditions: 

  • Where noise due to static electricity is generated. 
  • Where electro-magnetic field strength is high. 
  • Where radioactivity is present. 
  • Where power lines are located. 

• 

Do  not  use  the  product  in  a  place  where  electrical  surges  are 
generated. 

• 

Use  suitable  surge  protection  when  a  surge  generating  load  such 
as a solenoid valve is to be directly driven. 

• 

Prevent any foreign matter from entering this product. 

• 

Do not expose the product to vibration or impact. 

• 

Use the product within the specified ambient temperature range. 

• 

Do not expose the product to any heat radiation. 

• 

Use a precision screwdriver with flat blade to adjust the DIP switch.  

• 

Close the cover over the switches before power is turned on. 

• 

Do  not  clean  the  product  with  chemicals  such  as  benzene  or 
thinners. 

 

2 General Instructions 

2.1 Wiring 

Warning 

• 

Adjusting,  mounting  or  wiring  change  should  not  be  done  before 
disconnecting the power supply to the product. 

Electrical shock, malfunction and damage can result. 

• 

Do not disassemble the cables.  

• 

Use only specified cables. 

• 

Do  not  connect  or  disconnect  the  wires,  cables  and  connectors 
when the power is turned on. 

 

Caution 

• 

Wire the connector correctly and securely.  

Check  the  connector  for  polarity  and  do  not  apply  any  voltage  to  the 
terminals other than those specified in the Operation Manual. 

• 

Take appropriate measures against noise. 

Noise in a signal line may cause malfunction. As a countermeasure 
separate the high voltage and low voltage cables, and shorten the wiring 
lengths, etc. 

• 

Do not route input/output wires and cables together with power or 
high voltage cables. 

The product can malfunction due to interference of noise and surge 
voltage from power and high voltage cables to the signal line. Route the 
wires of the product separately from power or high voltage cables. 

• 

Take care that actuator movement does not catch cables. 

• 

Operate with all wires and cables secured.  

• 

Avoid bending cables at sharp angles where they enter the product. 

• 

Avoid twisting, folding, rotating or applying an external force to the 
cable.  

Risk of electric shock, wire breakage, contact failure and loss of control 
of the product can happen. 

• 

Fix  the  motor  cables  protruding  from  the  actuator  in  place  before 
use.  

The  motor  and  lock  cables  are  not  robotic  type  cables  and  can  be 
damaged when moved. 

• 

The actuator cables connecting the actuator and the controller are 
robotic  type  cables.  But  should  not  be  placed  in  a  flexible  moving 
tube with a radius smaller than the specified value. (Min. 50 mm) 

 
 
 
 
 
 
 

2 General Instructions (continued) 

• 

Confirm correct insulation of the product. 

Poor  insulation  of  wires,  cables,  connectors,  terminals  etc.  can  cause 
interference with other circuits. Also there is the possibility that excessive 
voltage or current may be applied to the product causing damage. 

 

2.2 Transportation 

Caution 

• 

Do not carry or swing the product by the cables. 

 

2.3 Mounting 

Warning 

• 

Observe the tightening torque for screws. 

Unless stated otherwise, tighten the screws to the recommended torque 
for mounting the product.  

• 

Do not make any alterations to this product. 

Alterations made to this product may lead to a loss of durability and 
damage to the product, which can lead to human injury and damage to 
other equipment and machinery. 

• 

When  an  external  guide  is  used,  connect  the  moving  parts  of  the 
product and the load in such a way that there is no interference at 
any point within the stroke. 

Do not scratch or dent the sliding parts of the table or mounting face etc., 
by striking or holding them with other objects. The components are 
manufactured to precise tolerances, so that even a slight deformation 
may cause faulty operation or seizure. 

• 

Do  not  use  the  product  until  you  verify  that  the  equipment  can  be 
operated correctly. 

After mounting or repair, connect the power supply to the product and 
perform appropriate functional inspections to check it is mounted 
correctly. 

• 

When  attaching  to  the  work  piece,  do  not  apply  strong  impact  or 
large moment. 

If an external force over the allowable moment is applied, it may cause 
looseness  in  the  guide  unit,  an  increase  in  sliding  resistance  or  other 
problems. 

• 

Maintenance space 

Allow sufficient space for maintenance and inspection. 

 

2.4 Handling 

Warning 

• 

Do not touch the motor while in operation. 

The surface temperature of the motor can increase to approx. 90°C to 
100°C due to operating conditions.  
Energizing alone may also cause this temperature increase.  
As it may cause burns, do not touch the motor when in operation. 

• 

If  abnormal  heating,  smoking  or  fire,  etc.  occurs  in  the  product, 
immediately turn off the power supply. 

• 

Immediately stop operation if abnormal operation noise or vibration 
occurs. 

If abnormal operation noise or vibration occurs, the product may have 
been mounted incorrectly. Unless operation of the product is stopped for 
inspection, the product can be seriously damaged. 

• 

Never touch the rotating part of the motor or the moving part of the 
actuator while in operation. 

There is a serious risk of injury. 

• 

When  installing,  adjusting,  inspecting  or  performing  maintenance 
on the product, controller and related equipment, be sure to turn off 
the power supply to each of them. Then, lock it so that no one other 
than  the  person  working  can  turn  the  power  on,  or  implement 
measures such as a safety plug. 

• 

In  the  case  of  the  actuator  that  has  a  servo  motor  (24  VDC),  the 
“motor  phase  detection  step"  is  done  by  inputting  the  servo  on 
signal just after the controller power is turned on. 
The  “motor  phase  detection  step”  operates  the  table/rod  to  the 
maximum  distance  of  the  lead  screw.  (The  motor  rotates  in  the 
reverse direction if the table hits an obstacle such as the end stop 
damper.) Take the “motor phase detection step” into consideration 
for the installation and operation of this actuator 
 
 
 

2 General Instructions (continued) 

 

Caution 

• 

Keep the controller and product combined as delivered for use. 

The product is set in parameters for shipment.  

If it is combined with a different product parameter, failure can result. 

• 

Check the product for the following points before operation. 

  • Damage to electric driving line and signal lines. 
  • Looseness of the connector to each power line and signal line. 
  • Looseness of the actuator/cylinder and controller/driver mounting. 
  • Abnormal operation. 
  • Stop function 

• 

When  more  than  one  person  is  performing  work,  decide  on  the 
procedures,  signals,  measures  and  resolution  for  abnormal 
conditions before beginning the work.  

• 

Also  designate  a  person  to  supervise  the  work,  other  than  those 
performing the work. 

• 

An  operation test should be  performed at low speed, start the test 
at a predefined speed, after confirming there are no problems. 

• 

Actual speed of the product will be changed by the workload. 

Before selecting a product, check the catalogue for the instructions 
regarding selection and specifications. 

• 

Do  not  apply  a  load,  impact  or  resistance  in  addition  to  a 
transferred load during return to origin. 

In the case of the return to origin by pushing force, additional force will 
cause displacement of the origin position since it is based on detected 
motor torque.  

• 

Do not remove the nameplate. 

 

2.5 Actuator with lock 

Warning 

• 

Do  not  use  the  lock  as  a  safety  lock  or  a  control  that  requires  a 
locking force. 

The lock used for the product with a lock is designed to prevent dropping 
of work piece. 
 

• 

For vertical mounting, use the product with a lock. 

If the product is not equipped with a lock, the product will move and drop 
the work piece when the power is removed. 

• 

"Measures  against  drops”  means  preventing  a  work  piece  from 
dropping  due  to  its  weight  when  the  product  operation  is  stopped 
and the power supply is turned off. 

• 

Do  not  apply  an  impact  load  or  strong  vibration  while  the  lock  is 
activated. 

If an external impact load or strong vibration is applied to the product, the 
lock will lose its holding force and damage to the sliding part of the lock 
or reduced  lifetime can result. The same situation will happen when the 
lock slips due to a force higher than its holding force, as this will 
accelerate the wear to the lock. 

• 

Do not apply liquid, oil or grease to the lock or its surroundings. 

When liquid, oil or grease is applied to the sliding part of the lock, its 
holding force will be reduced significantly. 

• 

Take  “measures  against  drops”  and  check  that  safety  is  assured 
before mounting, adjustment and inspection of the product. 

If the lock is released with the product mounted vertically, a work piece 
can drop due to its weight. 

 

2.6 Please refer to the auto switch references in “Best Pneumatics “ 

when an auto switch is to be used. 

 

2.7 Unpacking 

Caution 

• 

Check the received product is as ordered. 

If a different product is installed from the one ordered, injury or damage 
could result. 

 
 
 
 
 
 
 
 
 

Отзывы: