5 Adjustments
5-4
5.1.3 Monitoring Operation during Adjustment
Check the operating status of the machine and signal waveform when adjusting the servo gain.
Connect a measuring instrument, such as a memory recorder, to connector CN5 analog monitor
connector on the DRIVER to monitor analog signal waveform.
The settings and parameters for monitoring analog signals are described in the following sections.
(1) Connector CN5 for Analog Monitor
To monitor analog signals, connect a measuring instrument with cable (YASKAWA
CONTROLS CO., LTD) to the connector CN5.
Line Color
Signal Name
Factory Setting
White
Analog monitor 1
Torque reference: 1 V/100% rated torque
Red
Analog monitor 2
Motor speed: 1 V/1000 min
-1 *
Black (2 lines)
GND
Analog monitor GND: 0 V
(2) Monitor Signal
The shaded parts in the following diagram indicate analog output signals that can be
monitored.
DRIVER