Example of step data input (2)
〈
Positioning operation - Relative
〉
a b c d e f g h i j k
*Absolute: Distance from the origin position. / General setting method
*Relative: Feed from the current position. / This is used when simplified data.
Condition 1) 30mm position
→
Step no.0
→
Step no.0
(Move Method: Relative)
Condition 2) 30mm position
→
Step no.1
→
Step no.1
(Move Method: Relative)
Step data
No.
Move M
Speed
Position
Accel
Decel
Pushing F
TriggLV
Pushing Sp
Moving F
Area1
Area2
In pos
mm/s
mm
mm/s2
mm/s2
%
%
mm/s
%
mm
mm
mm
0 Relative
100
10.00
3000
3000
0
0
0
100
10.00
20.00
0.50
1 Relative
100
-10.00
3000
3000
0
0
0
100
10.00
20.00
0.50
Attainment point
:
50[mm]
0 10 20 30 40 50
Position:-10(Relative)
C
Stroke[mm]
Position:10(Relative)
C
0 10 20 30 40 50
Stroke[mm]
Attainment point
:
10[mm]
2021-05-20 10:32