- 11 -
3. Specifications
3. 1 Specifications
Basic specifications of the product.
Item
Specifications
Rated voltage
24 VDC±10%
Current consumption
200mA or less (When teaching box is not connected)
300mA or less (When teaching box is connected)
Applicable controller
Electric actuator controller (LEC series)
Product to be connected
Max. 5pcs.
I/O occupation area
(Input/Output)
Input 57words / Output 57 words
When conformity to UL is required, the electric actuator and controller should be used with a UL1310
Class 2 power supply.
【
Profibus spec
】
Item
Specifications
Fieldbus Profibus
DP
–V1
Device type
DP slave
Communication speed
Auto baud rate
Address setting range
0 to 125
ID Number
1414
Configuration file
GSD
Terminating resistor
None
Connecter type
D-sub
【
Controller IF communication spec.
】
Item
Specifications
Serial
communication
RS485 (Modbus protocol compliant)
Communication
speed
115.2k or 230.4kbps (Select 115.2kbps when the teaching box is connected)
Cable length
The cable for the teaching box (3m) and the electric actuator controller (5m x 5)
makes 28m of cable length. This is the maximum cable length.
3m
5m
5m
5m
5m
5m