JXCP1-TF2Z197EN

 

Page 2 of 2 

 

5 Setting 

5.1  Initial Setting 

  Appropriate setting is required in order to establish the communication 

of the controller (JXCP1) on the PROFINET network. 

  Please refer to the PLC setting software "SIMATIC Manager Version 

5.5 (STEP7) for the representative PROFINET master device. 

  The required setting method such as the GSDML file installation varies 

depending on which setting software will be used, so if software other 
than STEP7 is used, please refer to the operation manual of the 
applicable setting software. 

In order to move the electric actuator to a specific position, it is necessary 
to set up the patterns of operation with a PC using the controller setting 
software or by using a teaching box. This set up data will be recorded in 
the memory of the controller.

 

Refer to the Operation Manual on the SMC website (URL: 

https://www.smcworld.com

) for further setting details. 

 

5.2  Configuration 

  A GSDML file and icons file are required to configure the controller.  

The latest GSDML  file can be downloaded from the SMC website 
(URL: 

https://www.smcworld.com

)

 

6 LED Display 

Refer to the table below for the LED status. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Refer to the table below for the LED and controller status 

Controller status 

LED

 

PWR 

ALM 

SF 

BF 

When power is supplied 

Green 

LED is 

ON 

LED is 

OFF 

-

 

-

 

When PROFINET 
communication is normal 

LED is 

OFF 

LED is 

OFF 

Motor 
controller 

Controller 
alarm 
generated 

LED is 

OFF 

Red 

LED is 

ON 

Red 

LED is 

ON 

Controller 
system error 
generated 

Green 

LED is 

ON 

Red 

LED is 

ON 

Writing to 
controller 
Eeprom 

Green 

LED is 

flashing 

 

Caution 

Do not turn OFF the power supply for the controller or connect  / 
disconnect the cable while data is being written to EEPROM (PWR LED 
(green) is flashing). 
This is to avoid the possibility of incorrect / corrupt data (step data, 
parameter). 
 

 

7 How to Order 

Refer to the catalogue on the SMC website (URL: 

https://www.smcworld.com

) for the How to Order information. 

 

8 Outline Dimensions (mm) 

Refer to the drawings / operation manual on the SMC website (URL: 

https://www.smcworld.com

) for outline dimensions. 

 

9 Maintenance 

9.1  General Maintenance 

 Caution 

  Not following proper maintenance procedures could cause the product 

to malfunction and lead to equipment damage. 

  Before performing maintenance, turn off the power supply. Check the 

voltage with a tester 5 minutes after the power supply is turned OFF. 

  If any electrical connections are disturbed during maintenance, ensure 

they are reconnected correctly and safety checks are carried out as 
required to ensure continued compliance with applicable national 
regulations. 

  Do not make any modification to the product. 

  Do not disassemble the product, unless required by installation or 

maintenance instructions. 

 Caution 

  Maintenance should be performed according to the procedure 

indicated in the Operation Manual. 

  When equipment is serviced, first confirm that measures are in place 

to prevent dropping of work pieces and run-away of equipment, etc, 
then cut the power supply to the system. When machinery is restarted, 
check that operation is normal with actuators in the correct position. 

  Warning 

  Perform maintenance checks periodically. 

  Confirm wiring and screws are not loose. Loose screws or wires may 

cause unexpected malfunction. 

  Conduct an appropriate functional inspection and test after completing 

maintenance.  In  case of any abnormalities (if the actuator does not 
move, etc.), stop the operation of the system. Otherwise, an 
unexpected malfunction may occur and it will become impossible to 
ensure safety. Operate an emergency stop instruction to confirm safety. 

  Do not put anything conductive or flammable inside of the controller. 

  Ensure sufficient space around the controller for maintenance. 

 

10 Limitations of Use 

10.1 Limited warranty and Disclaimer/Compliance Requirements 

Refer to Handling Precautions for SMC Products. 

 

11 Product disposal 

This  product  shall  not  be  disposed of as municipal waste. Check your 
local regulations and guidelines to dispose of  this product correctly,  in 
order to reduce the impact on human health and the environment. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

12 Contacts 

Refer to 

www.smcworld.com

  o

www.smc.eu

  for  your  local distributor  / 

importer. 
 

 

URL

https://www.smcworld.com

 (Global)    

https://www.smc.eu

 (Europe) 

SMC Corporation, Akihabara UDX15F, 

4-14-1

, Sotokanda, Chiyoda-ku, Tokyo 

101 

0021

 

Specifications are subject to change without prior notice from the manufacturer.  
© 2021 SMC Corporation All Rights Reserved. 
Template DKP50047-F-085M

 

LED 

Details 

PWR 

Power supply 
status. 

OFF 

Power is not supplied 

Green LED is 

ON 

Power is supplied 

ALM 

Controller alarm 
status. 

OFF 

Normal operation 

Red LED is 

ON 

Alarm generated 

SF 

Controller 
status. 

OFF 

Normal operation 

Red LED is 

ON 

Alarm generated (Linked to 
ALM) 

BF 

PROFINET 
communication 
status 

OFF 

PROFINET communication 
is established. 

Red LED is 

flashing 

PROFINET communication 
is not established. 

Red LED is 

ON 

Both Port1 and Port2 are 
not connected. 

 