11
CJ2 series
Pressure: 0.5 MPa
Load ratio: 50 %
Stroke: 60 mm
Ø 6
Ø 10
Ø 16
CM2 series
Pressure: 0.5 MPa
Load ratio: 50 %
Stroke: 300 mm
Ø 20
Ø 25
Ø 32
Ø 40
CA2 series
Pressure: 0.5 MPa
Load ratio: 50 %
Stroke: 500 mm
Ø 50
Ø 63
Ø 80
Ø 100
Average speed [mm/s]
Average speed [mm/s]
0
100
200
300
400
500
600
700
800
0
100
200
300
400
500
600
700
800
For JSY1000, A, B port:
Ø
6
Horizontal
Vertical (Upward)
Optimum Actuation Size Chart of Air Cylinder
∗
Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open.
∗
The average speed of the cylinder is obtained by dividing the stroke by the total stroke time.
∗
Formula for load ratio: Load ratio = ((Load mass x 9.8)/Theoretical output) x 100 %
∗
Cylinder for horizontal use are based on the coeffi cient of rolling friction 0.1.
∗
Operating piston speed is different depending on the applicable cylinder. Refer to the cylinder catalogueue for details.
r