- 38 -
3. Installation Settings Tab
* To change the setting, set the security access level to the administration level.
(1) Select a valve option.
Check the product number, and then select a valve option that suits the type of the air gripper you are
using.
Nil: no symbol
N.O.
:
Normally open
N.C.
:
Normally closed
(2) Gripper operation completion waiting time
This is the set value for the waiting time after the valve is operated for the finger opening/closing action
to turn on.
Adjust the opening of the exhaust restrictor and enter an appropriate value according to the gripper
finger opening/closing operation time. The default value is 500ms. It can be set in the range of 0 to
1000ms.
(3) Status signal output to digital output port.
Select whether to output a status signal to the digital output port when
“Open/Close success” or
“Open/Close failure” is detected.
When
“Enabled” is selected:
Selection of the digital output port is enabled. If either of "Open/Close success” and “Open/Close
failure” is detected, the corresponding digital output port is turned on.
When
“Disabled” is selected:
The selection of the
digital output port is disabled. Even if either of "Open/Close success” and
“Open/Close failure” is detected, no status signal is output.
(4) Select a digital output port
Selected box operation is enable
d when “Output status signal to digital output port” is enabled. Select
the digital output port to which a status signal is output when “Open/Close success” or “Open/Close
failure” is detected.
Содержание JMHZ2-16D-X7400B-DTB-N
Страница 9: ... 8 3 Product Specifications 3 1 How to order ...
Страница 14: ... 13 3 5 2 JMHZ2 16D X7400B HC10DT N P ...
Страница 15: ... 14 3 5 3 JMHZ2 16D X7400B HC10 N P ...
Страница 33: ... 32 2 Tap the Extensions tab and confirm that the SMC Air Gripper is added to the list ...
Страница 34: ... 33 3 Tap the Presets tab and confirm that SMC Air Gripper is added to the list ...