background image

 

- 2 - 

    

       

       

       

       

High Pressure E/P Regulator 

       

       

       

       

Safety Instructions

    

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”

 

They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)

*1)

 , 

and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218-1992: Manipulating industrial robots -Safety.

 

 

  etc.

 

     

       
 
 

Caution

    

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

    

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

    

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

    

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications.

    

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person  who designs the  equipment or decides its specifications based  on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

    

The product specified here may become unsafe if handled incorrectly.

 

The assembly, operation and maintenance of machines or equipment including our products must be performed 
by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

    

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to be 

used in any of the following conditions.

    

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

 

Содержание ITVX Series

Страница 1: ...the product only after reading the Operation Manual carefully and understanding its contents Specifically read the safety instructions carefully Keep this operation manual available whenever necessary...

Страница 2: ...ng method P6 Setting method P8 Key locking function P9 Setting of min pressure max pressure and switch output P10 Mode of switch output P11 Reset function P12 Error indicating function P12 Detail sett...

Страница 3: ...eferring to its latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring the equipment 2 Only personnel with appropriate training sho...

Страница 4: ...rest sales branch 2 For any failure or damage reported within the warranty period which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty ap...

Страница 5: ...Therefore flush the piping thoroughly and mount a suitable filter to prevent foreign matter such as metal powder and dust from entering the product Take safety measures by installing safety devices e...

Страница 6: ...upted or shut off since the life of the product may be shortened The optional cable connector is a 4 wire type When the monitor output analogue output or switch output is not being used prevent the un...

Страница 7: ...ves relays etc 4 Turn off the power supply before inserting or removing the connector 5 Ground the F G terminal at the front of the main body Please note that the right angled cable connector does not...

Страница 8: ...ernative cable is used Current Voltage type ITVX2030 0 ITVX2030 1 ITVX2030 2 ITVX2030 3 Power supply 24 VDC Input signal 4 20mADC ITVX2030 0 0 20mADC ITVX2030 1 0 5VDC ITVX2030 2 0 10VDC ITVX2030 3 Wi...

Страница 9: ...cuit will operate Er 5 will be displayed and the operation will stop Please install a load to give an output current of 80 mA or less When a current of approx 150 mA or more is applied the over curren...

Страница 10: ...ot been entered Output pressure from this product and state of operation are changed by changing of each setting and function Each setting and function should be operated by trained and experienced op...

Страница 11: ...ed for approx 1 second Key lock is released current pressure is displayed Note Press key to cancel Locking the keys No Key operation LED Display current pressure is displayed Press key for 2 seconds o...

Страница 12: ...P9 Minimum pressure F_1 adjusting range Maximum pressure F_2 adjusting range 0 90 100 4 0 0 0 12 10 2 5 5 20m A 20m A 5V 10V 0 10 120 4 0 0 0 12 10 2 5 5 20m A 20m A 5V 10V 100 Note1 F_1 is adjustable...

Страница 13: ...output type ITVX2030 2 3 P_1 P_2 P_1 P_2 Window comparator mode Hysteresis mode O N O FF P_1 P_2 O N O FF P_1 P_2 P_1 P_2 0 Out of range mode The switch output turns on when set pressure is achieved O...

Страница 14: ...the power supply Reading or writing errors occurred in EEPROM Please execute Initialize refer to P15 when the ITVX does not operate normally after reconnecting the power supply Please contact SMC whe...

Страница 15: ...adjustment of gain The product can change the response time using this gain setting When the gain is changed to a larger value the response will be faster but there is a possibility that stability wil...

Страница 16: ...ved No Key operation LED Display Unlock keys refer to P9 Press S key for 2 seconds or more then go to detail setting mode To F03 by using the and keys displayed alternately Press S key displayed alter...

Страница 17: ...than 5 seconds to Turning off for 1 second Returns to the state immediately after turning on the power supply keys are locked LED display The range of the LED pressure display is different according t...

Страница 18: ...3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2012 SMC Corporation All Righ...