background image

 

- 6 - 

Wiring method and LED indication 

 

 CAUTION 

 

Proceed carefully, as incorrect wiring can cause damage. 

 

Use a DC power supply with sufficient capacity and a low ripple. 
Example: Class 2 voltage source. UL1310 compliant. 

 

Turn off the power supply to remove and insert the connector. 

 

Never rotate the right angled type connector as it is not designed to rotate. 

 

The  communications  cable  recommends  the  use  of  our  company 
PCA-1557633 (socket type). 

 

 

 

The line color is when the optional cable is used. 
 

Connection to external equipment

 

 
 
 
 
 
 
 

 

 

 

LED indication

 

Item 

Turning ON 

Turning OFF 

Blinking 

POWER 

Power ON(Green) 

Power OFF 

― 

MOD/NET 

ON line(Green) 

OFF line 

Communication 

unestablishment (Green) 

Fatal error(Red) 

Negligible error(Red) 

(I/O connection time out) 

 

POWER LED 

MNS LED 

Connector for 
Communication 
 

Connector for 
Power supply 

Power supply    wiring diagram 

 

3:GND 

1:+24V 

 

Power Supply

 

DC24V 

Communication wiring   
diagram 

 

5:CAN_L 

4:CAN_H 

3:V

 

2:V

 

1:DRAIN 

Master 
PLC 

2:No Connection 

4:No Connection 

Содержание ITV1000-DE Series

Страница 1: ...EL Series Product Number ITV1000 2000 3000 2090 DE Series Install and operate the product only after reading the Operation Manual carefully and understanding its contents Specifically read the safety...

Страница 2: ...ns P2 Handling precautions P4 Wiring method and LED indication P6 System configuration P7 Communication specification P7 Setting of dipswitch P8 Pressure setting and output monitoring P10 Communicatio...

Страница 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Страница 4: ...responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the...

Страница 5: ...oduct is interrupted or shut off while the power is still on the internal solenoid valve will continue to operate and a humming noise will be generated Turn off the power supply when supply pressure i...

Страница 6: ...ling this product and its wiring away from strong electric fields such as those of motors and power cables etc 3 Be sure to implement protective measures against load surge for inductive loads solenoi...

Страница 7: ...nds the use of our company PCA 1557633 socket type The line color is when the optional cable is used Connection to external equipment LED indication Item Turning ON Turning OFF Blinking POWER Power ON...

Страница 8: ...ifications Remarks Field bus DeviceNetTM Volume1 Edition3 8 Volume3 Edition1 5 EDS file ITV A EDS Down load from Web Slave type Group 2 Only Device type 00h Generic Device MAC ID 0 to 63 Due to the di...

Страница 9: ...and reset if necessary Setting procedure Loosen the screws of the switch cover Open the cover from the bottom upwards See drawing Set switches according to the following procedure After setting the sw...

Страница 10: ...clear the output pressure when the DeviceNetTM line causes a communication error due to disconnection Setting 9 Function Hold ON Hold the output pressure Clear OFF Exhaust the output pressure When swi...

Страница 11: ...command sending and receiving data Item Output from PLC Poll request Input to PLC Poll response Data size 2Byte 16bit 2Byte 16bit Communication data b15 b14 b1 b0 b15 b14 b1 b0 The I O data occupies t...

Страница 12: ...cover Use a soft cloth to remove stains Refer to the SMC website URL http www smcworld com for more information about troubleshooting This operation manual refers to all standard types and is partiall...