9. Specification for Option L
9- 1
9.1
Safety instructions
When handling the product, take care to the following precautions.
Warning
- Do not remove the auto drain with the air pressure remaining internally. If the compressed
air is left in the product, when some part is loosened, it may cause sudden lurching or
other unexpected accidents.
- When removing the panel, wear protective gloves to prevent injuries.
- There is a risk of touching drained waste liquid during replacement.
When draining, follow the user’s own procedure to keep operators safe. (E.g. Wear
protective goggles, apron and gloves to prevent contact with the drained condensate.)
- When oils can enter the drained condensate, waste water treatment is necessary. Follow the
bylaws or rules of the local municipality for disposal.
9.2
Specifications
The maximum operating pressure 1.6MPa. The float type auto drain used in the standard air dryer is
replaced with a heavy duty auto drain (ADH4000-04). The customer is required to mount the auto drain to
the air dryer.
Model
Item
IDU15E1-23-L
Auto drain type
Floating type
Auto drain valve type
N.O.
(normally opened: Released without
pressurization)
Working pressure range
0.05 to 1.6MPa
Max. drain discharge
400cc/min
(Pressure 0.7MPa, the case of water)
Specification for Option L
9
Note) Use for air compressor with flow more than 50L/min (ANR).
Parts shown in are accessories attached to the unit.