HRX-OM-L014
Error! Style not defined.
Error! Style not defined.
HRGC001-A HRGC002-A HRGC005-A
Error! Style not defined.Error! Style not defined.
1
st
edition : Jun. 2007
Error! Style not defined.
-7
6.4 Other Errors
How to check other errors
The cause and remedy for the failure that is not shown with alarm number is shown in Table 6-3.
Table 6-3 Cause and remedy for failure without alarm number
Content of
failure
Cause
Remedy
The power supply switch is not turned
on.
Turn on the power supply switch.
The GFCI is not turned on.
Turn on the GFCI.
No power supply
(The breaker for the power supply is
not turned on.)
Supply the power.
Insufficient capacity of breaker
Install adequate breaker referring to Table
3-2.
Trip of breaker due to short-circuit and
current leakage
Repair the short-circuited or current
leaking part.
The [POWER]
LED does not
light up.
Failure of the [POWER] LED
Replace the controller.
Failure of the [RUN] LED
Replace the controller.
The [RUN]
LEDdoes not
light up even
by truning on
the [START]
switch.
Failure of the [START] switch
Replace the controller.