![SMC Networks HEC002-A5 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/smc-networks/hec002-a5/hec002-a5_operation-manual_1299554054.webp)
Appendix
10-2
HEC002-A/HEC006-A
10.2
Calculation of dew point (from psychometric chart)
Fig.10-1 Moisture air diagram
1) Measure the ambient temperature and relative humidity.
2) Plot the ambient temperature on the horizontal axis (Ex. 24
C), and then draw a perpendicular line.
3) Find the intersection (A) of the curve, which is equal to relative humidity (Ex. 50%).
4) Draw a line from point (A) parallel to horizontal axis, and find the intersection (B) of the curve for 100%
relative humidity.
5) Draw a perpendicular line from the intersection at point (B) down to the horizontal axis and read the
Dew Point Temperature. (13
C in this case.)
*Therefore, moisture in the air starts to condensate when the air temperature becomes lower than this
temperature.
10.3
Power Supply Cable
Table 10-2 Power Supply Cable
Description
Specifications
Connector
Rating Voltage: 250V
Rating Current: 10A
Cable
Rating Voltage: 300V
AWG14
Do not use the included power supply cable for any purposes other
than connection to this product.
Relat
ive humidity (%)
B
A
100
90
80
70
60
50
45
40
35
30
55
4
Temperature (deg.C)
10 13
20
24
30
Содержание HEC002-A5
Страница 2: ......
Страница 20: ...Caution on Installation HEC002 A HEC006 A 3 4...
Страница 32: ...Specifications HEC002 A HEC006 A 6 4...
Страница 52: ...Alarm HEC002 A HEC006 A 9 6...
Страница 55: ......