FLEXIBLE ASSEMBLY SYSTEM
FAS200
User Manual for FAS200
- 95 -
The assembly is stopped al the end of belts of the linear transfer by a metal
piece, not allowing it to continue on its way and falll to the floor, waiting in this
position to be picked up and taken to the next belts
of next linear transfer. An photoelectric diffuse-
reflective sensor is used to detect the presence of
the pallet in this position.
Figure 102: Photoelectric sensor.
TECHNICAL DATA:
Dimensions:
Table of slotted aluminium section, 900 x 400 mm. Height 900 mm.
Air treatment unit:
Filter to 5 µm, pressure regulator and pressure gauge.
Control panel:
Start, stop, reset pushbuttons. Emergency stop button, main switch on/off,
mode selector (auto-man) and error pilot indicator.
Composition of module manipulators:
Vertical axis
Actuators:
- Double-acting parallel rod cylinder Ø10, Stroke:50mm (CXSM10-50), with
flow regulators and initial-end position detectors. Controlled by 5/2 way
monostable solenoid valve.
- Holding plate: 4 suction cups Ø20 (ZPT20CNK20-B5-A10), with vacuum
generating ejector (ZH10BS-06-06). Controlled by 3/2 way bistable solenoid
valve.
Sensors:
- Reed type magnetic detectors (D-Z73L).