FLEXIBLE ASSEMBLY SYSTEM
FAS200
User Manual for FAS200
- 59 -
F
i
g
u
r
e
4
2
:
Figure 63: Cover feeder.
There is a presence sensor in the form of a fiber optic
detector which allows the PLC to verify that really
there is at least a cover in the feeder to continue the
feeding procedure. This makes it possible to
determine when the covers loaded in the feeder have
run out.
Figure 64: Fiber optic sensor.
•
Cover measuring position:
The fact that covers of two different heights may be assembled necessitates a
height measuring device. Owing to the teaching and training objective for which
the cell has been designed, various solutions have been
used to perform similar operations, so that while
components such as pneumatic cylinders with correct
height detectors or analogue output touch probes have
been employed at other modules, this particular module
uses a digital transducer which provides a pulse output, as
it is a linear encoder.
Figure 65: Pneumatic
cylinder with stroke reading.