background image

1

Introduction

This manual describes how to install and use of EZ Switch (SMC-EZ108FDT).  It 
features 8 10/100Mbps  Auto-Negotiation  ports with one fiber module switch, 
provides the flexibility to fit into your working space with network environment.  The 
EZ Switch can be served to connect PCs, servers, hubs, bridges, other switches and 
routers.  It also act as a bridge between 10Mbps and 100Mbps networks segments.  

EZ Switch 10/100-108FDT supports 10Mbps and 100Mbps dedicated bandwidths in 
each port (excluding fiber module).  The device is built with plug & play, 
auto-negotiation on all ports, as well as half and full-duplex operations, 
store-and-forward transmission scheme, IEEE802.3x flow control and back pressure 
operation for easy installation and smooth transition from legacy 10Mbps to 
100Mbps switched-network.  Each port on the switch supports automatic MDI/MDI-X 
detection. This means that you can use either straight-through or crossover cables 
to connect to any other network device.

To ensure maximum safety and good funciton, please read carefully and follow all 
the directions in this manual to get successful installation and operation.  It is 
recommended that you should have a basic understanding of Local Area 
Networking (LAN) concepts as bridging, IEEE802.3 10BASE-T Ethernet, and 
IEEE802.3u 100BASE-TX Fast Ethernet.

Содержание EZ Networking SMC-EZ108FDT

Страница 1: ...EZ Swi...

Страница 2: ......

Страница 3: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 EZ Switch 10 100 Installation Guide From SMC EZ line of low cost workgroup LAN solutions Sep 2002 Pub 150000018700B R01...

Страница 4: ...is granted by implication or oth erwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2002 by 38 Tesla Irvine CA 92618 A...

Страница 5: ...e that incorporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinued products with their respective dates of di...

Страница 6: ...IDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUN...

Страница 7: ...6 Powering On the Switch 7 Verifying Port Status 7 Verifying System Operation 7 Applications 8 Product Spectifications 9 Base Unit 9 Physical Characteristics 9 Switching Criteria 9 Traffic Control 9...

Страница 8: ......

Страница 9: ...gotiation on all ports as well as half and full duplex operations store and forward transmission scheme IEEE802 3x flow control and back pressure operation for easy installation and smooth transition...

Страница 10: ...odule port All RJ 45 ports operate at 10 or 100 Mbps and support auto negotiation of speed duplex mode i e half or full duplex and flow control Note that when using auto negotiation speed transmission...

Страница 11: ...ber foot pads that come with this package on each of the 4 concave spaces located on the bottom of the first switch 2 Place the first switch on a firm flat surface where you want to install the stack...

Страница 12: ...VLAN grouping is activated VALN Setting On Group 1 Port 1 and Port 8 Group 2 Port 2 and Port 8 Group 3 Port 3 and Port 8 Group 4 Port 4 and Port 8 Group 5 Port 5 and Port 8 Group 6 Port 6 and Port 8...

Страница 13: ...10Mbps and 100Mbps Ethernet connections When inserting an RJ 45 plug be sure the tab on the plug clicks into position to ensure that it is properly seated Using the switch in a stand alone configurati...

Страница 14: ...t it is properly seated If you use an SC to ST converter for 62 5 125 micron cable only run cable from the Rx Tx port on the module to the Tx Rx port on the target device The fiber module operates at...

Страница 15: ...valid connection The switch monitors the link status for each port If any device is properly connected to the switch and transmitting a link beat signal the Link indicator will light up for the corres...

Страница 16: ...y used to filter and forward all traffic based on the destination address When traffic passes between devices attached to the same shared collision domain those packets are filtered from the switch Bu...

Страница 17: ...range 100 to 240V 10 50 to 60 Hz 3Hz Maximum Current 0 5ARMS max 110V 0 20ARMS max 240V Power Consumption 13 Watts max 100 240 VAC Heat Dissipation 137 BTU hr max 100 240 VAC Temperature Operating 10...

Страница 18: ...y that the proper cable type is used and its length does not exceed specified limits Check the adapter on the attached device and cable connections for possible defects Replace the defective adapter o...

Страница 19: ...ohm Category 5 cable for 100 Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Schematics for both straight and crossover twisted pair ca...

Страница 20: ...een the equipment and receiver Connect the equipment into an outlet on a circuit different from the one which the receiver is connected to Consult the dealer or an experienced radio TV technician for...

Страница 21: ......

Страница 22: ...3 Fax 39 02 739 14 17 Benelux 31 33 455 72 88 Fax 31 33 455 73 30 Central Europe 49 0 89 92861 0 Fax 49 0 89 92861 230 Switzerland 41 0 1 9409971 Fax 41 0 1 9409972 Nordic 46 0 868 70700 Fax 46 0 887...

Отзывы: