background image

EX600-TFM07GB

Installation & Maintenance Manual

Fieldbus System - Handheld terminal

Type  EX600-HT1

1. Safety Instructions

WARNING

CAUTION

Do not operate the product beyond the specification range.
Do not use the product for flammable or harmful gases or liquids.
Fire, malfunction, or damage to the product can result.
Please confirm the specifications before use.

Do not operate the product in an environment where flammable
or explosive gases may be present.
Fire or an explosion can result.
This product is not designed to be explosion proof.

The following instructions must be followed during maintenance:

• Turn off the power supply.
• Stop the air supply, exhaust the residual pressure and make sure that

the air is released to atmosphere before performing maintenance.

Otherwise injury can result.

Do not apply pressure to the LCD display.

This may cause damage or injury.

Do not operate the device with wet hands.
There is a risk of electric shock.

5. Names / Functions of individual Parts

No.

Name

Description

3

Handheld Terminal
cable

Cable to connect the SI Unit to the Handheld
Terminal.

5

Cursor move
button

(

,

,

,

This button is used to move the cursor in LCD
display upward/downward and right/left
direction. Select the required item using this
button. Use this button to increase/decrease or
turn ON/OFF the setting value.

10

Power LED

The Power LED (Green) turns ON when the
Handheld Terminal is connected with an EX600
SI Unit and power supply for Control/Input is
ON.

4

ENTER button

(

)

In selecting screen, this button is used for
selecting the required item. In setting screen,
pressing this button registers the selected
contents.

6

F2 button (

)

This button functions according to the indication
or instruction displayed on the screen.

7

F1 button (

)

8

Escape button 
(

)

In selecting screen, this button is used to return
to the previous screen. Pressing this button
cancels the setting contents.

1

LCD display

2

Connector

Connector for Handheld Terminal cable.

Displays the operation items and information
about the unit.

9

Error LED

The Error LED (Red) turns ON when EX600
diagnostics error occurs. (Refer to the
"Troubleshooting" and "Error Code" section for
further details.)

Mark at cable end

Mark on the unit

Projected 
portion

6. Wiring

2. How to Order

3. Specifications

4. Outline dimensions(mm)

<SPEEDCON Wiring method>

Set the projected portion of the cable connector metal ring (plug /
socket) to the mark at cable end.

Push the connector straight to insert it into the receptacle of the unit.
If inserted without aligning the mark, the connector will not mate with
the receptacle.

Refer to the catalogue or operation manual for this product.

Refer to the catalogue or operation manual for this product.

Refer to the catalogue or operation manual for this product.

The forced input/output function is used to change the signal 
status forcibly. 
When operating this function, be sure to check the safety of the
surroundings and the installation.
Otherwise injury or equipment damage could result.

Erroneous parameter setting can result in malfunction. 
Be sure to confirm the settings.
Otherwise injury or equipment damage could result.

When setting the parameters to the factory defaults, unpredictable
operation of connected equipment may occur.
It is essential to carry out this operation paying attention to safety.
Otherwise injury or equipment damage could result.

1

3

2

4

5

6

7

8

9

10

1. Safety Instructions (continued)

Perform a proper functional check after completing maintenance.
Stop operation if the equipment does not function properly.
Safety cannot be assured due to unexpected malfunction.

Switching the HOLD/ CLEAR function selection mode, will switch
the operation of the input / output signal and emergency stop, so
pay due attention to safety when setting.
There is a risk of injury and equipment damage.

Do not disassemble, modify (including change of printed circuit
board) or repair this product.
Injury or failure can result.

<Wiring Method 

(connecting Handheld Terminal connector)

>

When inserting the connector into the Handheld Terminal, insert
the connector straight in until it clicks into place.

<Wiring Method (connecting to the SI Unit)>

The M12 cable connector is connected to the  "connector for
Handheld Terminal" on the SI Unit. The method of connecting
the cable to the SI Unit is explained in the "<SPEEDCON Wiring
method>" section.

If instructions are not followed there is a
possibility of serious injury or loss of life.
If instructions are not followed there is a
possibility of injury or equipment damage.

In extreme conditions, there is a possible result
of serious injury or loss of life.

DANGER

WARNING

CAUTION

These safety instructions are intended to prevent hazardous situations
and/or equipment damage.
These instructions indicate the level of potential hazard by label of 
"DANGER", "WARNING"or "CAUTION", followed by important safety
information which must be carefully followed.
To ensure safety of personnel and equipment the safety instructions in
this manual and the product catalogue must be observed, along with
other relevant safety practices.

Отзывы: