-18-
No.EX##-OMP0025
Data bit
•SI unit input/output data bit
Address
Data bit
EX250-SAS3/-SAS7
EX250-SAS5/-SAS9
D0
IN0 / OUT0
IN0 / OUT0
D1
IN1 / OUT1
IN1 / OUT1
D2
IN2 / OUT2
IN2 / OUT2
ADDR1
D3
IN3 / OUT3
IN3 / OUT3
D0
IN4 / OUT4
D1
IN5 / OUT5
D2
IN6 / OUT6
ADDR2
D3
IN7 / OUT7
-
•Status register
It is possible to check the peripheral fault error (a blown input block fuse or detecting over current of input
power supply) by monitoring the status bit S1, which complies with the AS-i Version 2.1.
It is possible to confirm the peripheral fault error only by status register on the ADDR1 side for
EX250-SAS3/-SAS7 which occupy 2 slaves.
Note
Turn off the power supply and remove the cause immediately when over current load is connected with
the input block, and the peripheral fault error occurs by over current detection. Using with the peripheral
fault error can cause unit damage.