![SMC Networks EX12-SCM Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/smc-networks/ex12-scm-series/ex12-scm-series_operation-manual_1300549021.webp)
-20-
No.EX##-OMM0008-B
∗
1: General purpose status
Bit
Names
Explanation
0 -
-
1 -
-
2
Network Power Warning
The network power supply voltage has fallen below the threshold value.
When it has fallen below the threshold: ON
3
UNIT Total time Warning
The total energizing time of the product has exceeded the threshold value.
When it has exceeded the threshold: ON
4 -
-
5 -
-
6
Response Time Warning
Any of monitored operation time is outside of range: ON
7
Maintenance Counter Warning
Any of output monitored operation time is outside of range: ON
Communication Error Log object (0x96)
ID
Meaning
GET
SET
Value
0x01 Revision
О
-
0003H
Attributes
0x02 Max Instance
О
-
0004H
Cord
Meaning
Parameter option
Object class
Services
0x0E Get_Attribute_Single -
ID
Meaning
GET
SET
Value
0x64 Error Code
О
-
Error code
0: No error
1: Connection
Time out
2: Unused
3: MAC ID duplicated
Repeater
configuration error
0x67 Network Power Voltage
О
-
Network voltage
when error occurs
0x68 Run Hours
О
-
Energizing time
when error occurs.
Hour
Attributes
0x69 Manchester Error Rate
О
-
Error
code
Cord
Meaning
Parameter option
0x05 Reset -
Object instance
Services
0x0E Get_Attribute_Single -