-13-
No.EX##-OMM0008-B
•
Connection of terminal block for round cable
1, Removal of protective coating
Remove the protective coating, taking care not to damage the sheath of the internal signal cable.
2, Removal of sheath of signal cable
Remove the sheath of the signal cable to a length corresponding to the crimped part of the
crimping terminal used.
3, Mounting of crimping terminal
Use the crimping terminal for wiring. Do not connect electrical wires which are just twisted directly
to the terminal block.
4, Mounting to the connector
The available crimped terminal is M3 type.
The terminal screws should be firmly tightened to 0.3 to 0.5 Nm.
2. Power supply wiring (Solenoid valve power supply)
Connect the wiring for the solenoid valve power supply to the power supply connector (EX9-CP2) etc.