Electro Industries ProtoCessor Start-up Guide

 

Page 2 of 32

 

Technical Support 

Thank you for purchasing the ProtoCessor for Electro Industries.  

 

Please call Electro Industries for technical support of the ProtoCessor product. 

 

Sierra Monitor Corporation does not provide direct support. If Electro Industries needs to escalate the 

concern, they will contact Sierra Monitor Corporation for assistance.  

 

Support Contact Information:  

Electro Industries, Inc. 

2150 West River Street 

PO Box 538 

Monticello, MN 55362 

 

Customer Service: 

800.922.4138 

763.295.4138  

 

Email

[email protected]

 

 

Website: 

www.electromn.com

 

 

 

 

07/10/2019     BI806

Содержание Electro Industries ProtoCessor

Страница 1: ...4 Start up Guide For Interfacing Electro Industries Products Meter To Building Automation Systems LonWorks and SMC Cloud APPLICABILITY EFFECTIVITY Explains ProtoCessor hardware and how to install it T...

Страница 2: ...toCessor product Sierra Monitor Corporation does not provide direct support If Electro Industries needs to escalate the concern they will contact Sierra Monitor Corporation for assistance Support Cont...

Страница 3: ...LonWorks port to the field protocol cabling Section 4 3 4 Connect a PC to the ProtoCessor via Ethernet cable Section 5 1 5 Ethernet Network Use a browser to access the ProtoCessor FS GUI to change th...

Страница 4: ...etting IP Address for the Field Network 13 6 Commissioning ProtoCEssor on a LonWorks Network 15 6 1 Commissioning ProtoCessor FPC ED4 on a LonWorks Network 15 6 1 1 Instructions to Upload XIF File fro...

Страница 5: ...LonWorks Terminal Connector 10 Figure 8 Ethernet Port Location 11 Figure 9 FS GUI Landing Page 13 Figure 10 Changing IP Address via FS GUI 14 Figure 11 LonWorks Service Pin Location 15 Figure 12 Samp...

Страница 6: ...tors and end users LonMark International has developed extensive product certification standards and tests to provide the integrator and user with confidence that products from multiple manufacturers...

Страница 7: ...th Sierra Monitor s SMC Cloud The SMC Cloud allows technicians the OEM s support team and Sierra Monitor s support team to remotely connect to the ProtoCessor The SMC Cloud provides the following capa...

Страница 8: ...al number of registers presented the device s attached to the ProtoCessor cannot exceed Part number Total Registers FPC ED4 1564 1 500 Figure 2 Supported Point Count Capacity Devices Registers Per Dev...

Страница 9: ...Electro Industries ProtoCessor Start up Guide Page 9 of 32 4 INTERFACING PROTOCESSOR TO DEVICES 4 1 ProtoCessor Mounted onto Board Example Figure 5 Mounted ProtoCessor Example 07 10 2019 BI806...

Страница 10: ...nnection Ports 4 3 Wiring Field Port to LonWorks Network Wire the LonWorks device network to the ProtoCessor LonWorks Terminal o Use approved cable per the FT 10 installation guidelines LonWorks has n...

Страница 11: ...92 168 1 24 Subnet Mask is 255 255 255 0 If the PC and ProtoCessor are on different IP networks assign a static IP Address to the PC on the 192 168 1 xxx network For Windows 10 Find the search field i...

Страница 12: ...green then the IP Address doesn t need to be changed the ProtoCessor is already on the same subnet Skip the rest of the section Select Network Settings in the Configure Device window Modify the IP Ad...

Страница 13: ...e ProtoCessor the default Ethernet address is 192 168 1 24 o If using the FieldServer Toolbox Section 5 1 2 click the Connect button NOTE If the IP Address of the ProtoCessor has been changed the IP A...

Страница 14: ...at managed switch router Click the System Restart button at the bottom of the page to apply changes and restart the ProtoCessor Unplug Ethernet cable from PC and connect it to the network switch or ro...

Страница 15: ...ween the PC and ProtoCessor The default IP Address for the ProtoCessor is 192 168 1 24 Subnet Mask is 255 255 255 0 If the PC and ProtoCessor are on different IP networks assign a static IP Address to...

Страница 16: ...IP Address of ProtoCessor fserver xif o Example 192 168 1 24 fserver xif If the web browser prompts to save the file save the file onto the PC If the web browser displays the xif file as a web page s...

Страница 17: ...xecutable file and complete the installation Connect a standard Cat 5 Ethernet cable between the user s PC and ProtoCessor Double click on the FS Toolbox Utility and click Discover Now on the splash p...

Страница 18: ...he ProtoCessor into the web browser or use the FieldServer Toolbox to connect to the ProtoCessor Click on Diagnostics Button then click on view and then on connections If there are any errors showing...

Страница 19: ...bservations of LEDs on ProtoCessor Appendix A 4 o Check baud rate parity data bits stop bits o Check device address o Verify wiring o Verify device is connected to the same subnet as the ProtoCessor F...

Страница 20: ...after power up It will turn off after 5 seconds A steady red light will indicate there is a system error on ProtoCessor If this occurs immediately report the related system error shown in the error s...

Страница 21: ...pture utilities are embedded in the FS GUI web interface Starting a diagnostic capture takes a snapshot of the loaded configuration files and a log of all the communications over a specified period of...

Страница 22: ...Start up Guide Page 22 of 32 Step 1 Take a Log o Click on the diagnose icon of the desired device o Ensure Full Diagnostic is selected this is the default NOTE If desired the default capture period c...

Страница 23: ...period to finish then the Diagnostic Test Complete window will appear Step 2 Send Log o Once the Diagnostic test is complete a zip file is saved on the PC o Choose Open to launch explorer and have it...

Страница 24: ...ic Capture is complete email it to technical support The Diagnostic Capture will accelerate diagnosis of the problem Open the FieldServer FS GUI page Click on Diagnostics in the Navigation panel Go to...

Страница 25: ...address bar o Default IP Address is 192 168 1 24 o Use the FS Toolbox utility if the IP Address is unknown Appendix A 1 3 Click on the Diagnostics Debugging button 4 In the Navigation Tree on the lef...

Страница 26: ...restricted access to the ProtoCessor The User account can view any ProtoCessor information but cannot make any changes or restart the ProtoCessor The password needs to be a minimum of eight characters...

Страница 27: ...Stgs SNVT_count_f Differential Deg_F nvi nvoDifferentialF SNVT_count_f Troubleshooting Stage Code nvi nvoTrblshtStgCde SNVT_count_f 0 to 10VDC No or Yes nvi nvo0to10VDC SNVT_count_f Stage Seq Minutes...

Страница 28: ...Electro Industries ProtoCessor Start up Guide Page 28 of 32 Differential Deg_C nvi nvoDifferentialC SNVT_count_f 07 10 2019 BI806...

Страница 29: ...r Temperature F ST Supply Temperature F Current Stage Code Number of stages currently ON Mode 1 Setpoint 2 TS A Reset 3 0 10 VDC Input 4 Troubleshooting Fault Counts 0 9999 1 Auto HL 2 Bender 3 LWCO 4...

Страница 30: ...roubleshooting Stage Code 0 15 Default 0 0 10VDC YES NO Default NO Stage Sequence Minutes 0 99 minutes Default 1 Boiler Type 1 Single Default 2 Lead 3 Lag Lag Boiler Delay 0 999 minutes Default 15 For...

Страница 31: ...nge without notice Figure 19 Specifications Appendix D 1 1 Compliance with UL Regulations For UL compliance the following instructions must be met when operating ProtoCessor The units shall be powered...

Страница 32: ...n or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from batter...