Air Dryer
9 Specification for Option L
9-3Specification of heavy duty auto drain (ADH4000-04)
9 - 2
IDX-OM-K021
9-3 Specification of heavy duty auto drain (ADH4000-04)
Note) Use for air compressor with flow more than 1.77SCFM (ANR) [3 m
3
/ h (ANR)] .
9-4 Maintenance
1. Check drain condition periodically (more than once a day).
Then push flushing button to open exhaust valve.
2. Pilot air is exhaust from the port indicated in the figure. Do not cover this exhaust port.
Clean exhaust port so that port is not blocked by dust, etc.
3. Close the ball valve before removing the heavy duty auto drain and open the bleed valve or push
the flushing button and confirm air pressure is released.
Model
IDFB55E/75E-46
□
-L
Order number (service parts)
ADH-E400
Auto drain type
Floating type
Auto drain valve type
N.O(normally opened: Open in the case of pressure loss)
Max. operating pressure
240psig (1.6MPa)
Working pressure range
7.5 to 240psig (0.05 to 1.6MPa)
Working fluid
Compressed air
Max. drain discharge
0.014SCFM(Pressure 0.7MPa,the case of water)
IDFB Series
Flush button
Body
Bleed valve
Pilot exhaust port
open