Sensor unit

Amplifier unit

Direct mounting type

Rail mounting type

Specifications

Sensor unit

Mounting

Applicable amplifier unit

Status indication

Electrical entry

Lead wire

Impact resistance

Insulation resistance

Withstand voltage

Ambient temperature

Enclosure

Weight

D-RNK, D-RPK

Operating position: red light is ON. Suitable operating position: green light is O

Grommet

Rail mounting

Oil proof vinyl heavy insulation cable  ø3.5  0.14 mm

2

  4 cores  3 m

With one e-con connector 

Note)

980 m/s

2

50 M

 (500 VDC) between lead wire and case

1000 VAC for 1 min. between lead wire and case

–10 to 60 

°

C

IP67

58 g (with connector)

D-F7K

Direct mounting

D-Y7K

Note) The e-con connector is not attached to the lead wire. They will be supplied loose in the same shipme

Internal Circuit

Model

Amplifier unit (with sensor unit)

Applicable sensor unit

Application

Power supply voltage

Current consumption

Output specification

Load voltage

Load current

Internal voltage drop

Leakage current

Response time

Status indication

Electrical
entry

Connection
to sensor

Power supply/
output cable

Lead wire

Impact resistance

Insulation resistance

Withstand voltage

Ambient temperature

Enclosure

D-F7K, D-Y7K

For relay and PLC

12 to 24 VDC

40 mA or less

NPN open collector  Two outputs

28 VDC or less

80 mA or less

1.5 V or less

100 

µ

A or less

1 ms or less

e-con connector

Grommet

Oil proof vinyl heavy insulation cable  ø3.5  0.14 mm

2

  4 cores  3 m

98 m/s

2

50 M

 (500 VDC) between lead wire and case

1000 V AC for 1 min. (between lead wire and case)

–10 to 60 

°

C

IP40

READY: Red light emitting diode when the piston position detected.

(When the sensor is connected).

OUT 1: Green light emitting diode when ON

OUT 2: Orange light emitting diode when ON

D-RNK

PNP open collector  Two output

D-RPK

Model

D-

7K

Vsw (Brown)

GND (Blue)

SOUT 1 (Black)

SOUT 2 (White)

Amplifier unit

D-RNK

D-RPK

Detective

sensor

Switch

main circuit

Sensor unit

Trimmer Auto Switch

D-

7K/D-R

K

DC (+)

(Brown)

Brown

Main circuit

Main circuit

White

Blue

Black

Sensor

12 to 24
V DC

DC (–)

(Blue)

OUT 1

(Black)

OUT 2

(White)

Brown

White

Blue

Black

Load

Load

4

3

2

1

DC (+)

(Brown)

Sensor

12 to 24
V DC

DC (–)

(Blue)

OUT 1

(Black)

OUT 2

(White)

Load

Load

4

3

2

1

Содержание D-F7K

Страница 1: ...actuator OUT1 Trimmer OUT2 Trimmer Operating range of sensor LED of sensor is on OUT1 Detecting range Output ON Green LED is on Adjustable by trimmer Adjustable by trimmer Large work piece Medium work piece Small work piece OUT2 Detecting range Output ON Orange LED is on OUT1 and OUT2 are adjustable separately Can be mounted on a standard actuator Amplifier two types of mountin Large work piece Me...

Страница 2: ...nt Response time Status indication Electrical entry Connection to sensor Power supply output cable Lead wire Impact resistance Insulation resistance Withstand voltage Ambient temperature D F7K D Y7K For relay and PLC 12 to 24 VDC 40 mA or less NPN open collector Two outputs 28 VDC or less 80 mA or less 1 5 V or less 100 µA or less 1 ms or less e con connector Grommet Oil proof vinyl heavy insulati...

Страница 3: ... Adjustment must be undertaken while the sensor unit is removed from the actuator Refer to the operation manual for details Sensor unit 1 Indicator light Red light turns ON when sensor detects the magnet field Green light is ON durin the suitable position to detect the magne field including most sensitive position ø3 2 mounting hole M2 5 x 4L slotted set screw Fixes the sensor to the actuator 2 D ...

Страница 4: ...46 5 5 12 5 7 7 2 6 3000 ø3 5 21 1 6 30 OUT1 OUT2 READY TRIMMER SWITCH SMC D RNK 2 ø3 5 SMC D F7K Most sensitive position D Y7K Most sensitive position SMC M2 5 x 4L 11 1 7 15 4 23 8 3 2 6 2 8 5 4 6 3000 2 5 6 2 33 2 5 10 6 0 4 ø3 5 ø3 2 ø3 5 12 5 3000 Connector for sensor e con ...

Страница 5: ...latest catalogue information with a view to giving due consideration to any possibility of equipment failure when configuring a system 2 Only trained personnel should operate pneumatically operated machinery and equipment Compressed air can be dangerous if handled incorrectly Assembly handling or maintenance of pneumatic systems should be performed by trained and experienced operators 3 Do not ser...

Страница 6: ... unit and 98m s2 or more for amplifier un while handling Although the body of the switch may not be damaged th inside of the switch could be damaged and cause malfunction 2 Do not carry a cylinder by the auto switc lead wires Never carry a cylinder by its lead wires This may not on break the lead wires but it may cause internal elements of th switch to be damaged by the stress 3 Mount switches usi...

Страница 7: ...micals Consult SMC if auto switches will be used in an environment with coolant cleaning solvent various oils or chemicals If auto switches are used under these conditions for even a short time they may be adversely affected by improper insulation malfunction due to swelling of the potting resin or hardening of the lead wires 5 Do not use in an environment with temperature cycles Consult SMC if sw...

Страница 8: ...ors please consult the manufacturers of the respective connectors 1 2 3 4 Part A 1 2 3 4 20mm or more Sheath Insulator Connector no 1 2 3 4 Wire core colour Black SOUT1 Blue GND White SOUT2 Brown Vsw Manufacturer Tyco Electronics AMP Part no 1473562 4 Manufacturer OMRON Corporation IDEC IZUMI Corporation Part no PFP M BNL6 Washer M3 x 16L Claw 2 OUT1 OUT2 TRIMMER SWITCH READY SMC OUT1 OUT2 TRIM ME...

Отзывы: