Auto Switch Common Precautions 

Design and Selection 

Warning 

(1) Check the specifications. 

If the auto switch is used with an excessive load or used outside of the specifications, it may cause damage or 
malfunction. 
The product cannot be guaranteed if is used outside of the specification range. 

(2) Caution for use in an interlock system. 

When an auto switch is used in an interlock system which requires high reliability, provide a double interlock system, 
for example a mechanical protection system, for extra safety, or by also using another switch (sensor) together with 
the auto switch. 
Check the product regularly in order to confirm normal operation. 

(3) Do not disassemble, modify (including changing the printed circuit board) or repair. 

An injury or failure can result. 

 

Caution 

(1) Pay attention to the length of time the auto switch will operate at an intermediate stroke position. 

When an auto switch is placed at an intermediate stroke position, and a load is driven during the time when the piston 
passes, the auto switch will operate, but if the piston speed is too great, the operating time will be shortened, and the 
load may not operate correctly. 
The maximum piston speed is: 

Auto switch operating range [mm]

V [mm/s] = 

Load operating time [ms] 

×1000 

(2) Take precautions when multiple actuators are used close together. 

When using two or more actuators with auto switches in close proximity to each other, maintain a minimum separation 
distance of at least 40 mm. (If the separation distance is specified for the actuator series, then use that value). 
The auto switches may malfunction due to magnetic field interference. 
Use of a magnetic screen plate (MU-S025) or commercially available magnetic screening tape can reduce the 
interference of magnetic fields. 

(3) Provide sufficient space for maintenance. 

When designing an application, allow sufficient clearance for maintenance and inspection. 

(4) Never mount the actuator with auto switch in a location that will be used as a footrest. 

The product may be damaged if excessive force is applied by stepping or climbing onto it. 

(5) Design the circuit to prevent reverse current during open circuit conditions or when the product is forced to 

operate for functional checks. 

Reverse current can cause product damage or malfunction. 

(6) Precautions for mounting an auto switch 

When n number of auto switches is specified for mounting, this indicates the maximum number of auto switches 
based on the physical dimensions of the actuator. 
The detection distance varies depending on the auto switch mounting structure and the auto switch body dimensions. 
For this reason, the switch may not always be mounted at the required detection distance or at the required position. 

(7) Limitations of the detection position. 

There will be mounting positions or surfaces where the auto switch cannot be mounted due to physical interference 
(e.g. rear side of the foot bracket), depending on the mounting conditions of the actuator. 
Select an auto switch after confirming that the switch mounting position does not interfere with the mounting bracket 
(e.g. trunnion, reinforcement ring). 

Содержание D-F6# Series

Страница 1: ...No D S OMI0002 B PRODUCT NAME Solid state auto switch MODEL Series Product Number D F6 Series ...

Страница 2: ...tions 2 Model Indication and How to Order 11 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 13 Installation 13 Circuit diagram 14 Troubleshooting 15 Specifications 19 Specifications 19 Dimensions 20 Operating range 21 ...

Страница 3: ... of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to r...

Страница 4: ...lity a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalogue for the particular products 2 Vacuum pads are excluded from this 1 year warra...

Страница 5: ...rmful fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can result This product is not designed to be explosion proof Do not use the product in a place where static electricity is a problem Otherwise it can cause failure or malfunction of the system If using t...

Страница 6: ...erform appropriate functional inspections and leak tests Stop operation if the equipment does not function properly Safety cannot be assured in the case of unexpected malfunction Be sure to confirm the wiring condition This series including this product is not equipped with excessive current protection Therefore incorrect wiring and or a short circuited load could damage and or burn this product ...

Страница 7: ...ce of at least 40 mm If the separation distance is specified for the actuator series then use that value The auto switches may malfunction due to magnetic field interference Use of a magnetic screen plate MU S025 or commercially available magnetic screening tape can reduce the interference of magnetic fields 3 Provide sufficient space for maintenance When designing an application allow sufficient ...

Страница 8: ...n at the end of stroke Some actuator and cylinder series have their own setting methods In such cases follow the instructions given 6 Check and adjust the actual auto switch operation during installation The auto switch may not operate in the correct actuator mounting position due to the installation environment Also check and adjust the auto switch operation when used in intermediate stroke posit...

Страница 9: ...e elasticity of lead wires applications in welding sites etc 7 Do not use in direct sunlight 8 Do not mount the auto switch in locations where it is exposed to radiant heat 9 The auto switch is CE marked but not immune to lightning strikes Take measures against lightning strikes in the system Maintenance Warning 1 Removal of equipment and exhausting the compressed air When equipment is to be remov...

Страница 10: ...n leakage current flow to the load will be n times larger when n auto switches are connected in parallel 5 The solid state auto switch output will be unstable for 50 ms after power is supplied During the time after supplying power the input device e g PLC relay may consider the ON position as OFF output or the OFF position as ON output Please set up the application to consider the signals will be ...

Страница 11: ...cation where surges are generated When there are units solenoid lifter high frequency induction furnace motor etc which generate a large amount of surge in the area around the actuator with solid state auto switches this may cause damage to the auto switch internal circuit ...

Страница 12: ... D S OMI0002 B Model Indication and How to Order D F6 Output type Lead wire length Symbol Content Symbol Content N 3 wire NPN output Nil 0 5 m P 3 wire PNP output L 3 m B 2 wire Z 5 m Summary of Product parts ...

Страница 13: ...en the switch is turned on Most sensitive position Indicates the center position of the sensor most sensitive and becomes the center of operating range Auto switch which absorb current from the signal line during ON status NPN OUTPUT Auto switch which output current from the signal line during ON status PNP OUTPUT Reed type auto switch Auto switch to output ON OFF by mechanical contact Sequence co...

Страница 14: ...equired tightening torque of the set screw width across flats 3 mm is 0 8 to 1 4 Nm The followings are the recommended tools Description Part number Screw mounting jig D F6B 650 Setting the detecting position Set the actuator at the stroke end Set the switch in the area to where the auto switch red lamp light Detecting actuator end Based on A and B dimensions in the actuator catalogue set the swit...

Страница 15: ... 14 No D S OMI0002 B Circuit diagram D F6N D F6P D F6B Sink input mode D F6B Source input mode ...

Страница 16: ...SMC Switch output stays OFF Applicable actuator Switch failure Switch failure Wrong selection Refer to reference No 4 Normal Switch failure Select 50 types Refer to reference No 6 Indicator light stays OFF Indicator light stays ON Refer to reference No 1 Detection incorrect Switch output stays ON Refer to reference No 2 Refer to reference No 3 Switch output operate correctly Normal Indicator light...

Страница 17: ...lure 2 wire type Check if the switch wiring connection is reversed Brown Blue Correct wiring Refer to Circuit diagram on page 14 2 Output stays ON Display stays OFF Switch failure 3 wire type Replace the switch Not match with load specification 2 wire type Check if load specification satisfy the formula below Load ON voltage Switch leak current x n x Load resistance or load OFF current Switch leak...

Страница 18: ... 0 8 to 1 4 Nm Stop position displacement of the piston Check if the stroke stop position is Inconsistent Stabilize stop position Correction of displacement cushion Presence of magnetic field generating source around the cylinder Electric welding machine conductor Strong magnet Use the shield between magnetic field generating source and cylinder Influence of magnetic field of adjacent cylinder 20 ...

Страница 19: ...acket or set screw Fix at the right position with right torque Tightening torque 0 8 to 1 4 Nm Wiring failure Condition of connecting part connector contact pin crimp terminal Correct wiring Re wiring of connecting part Lead wire disconnection Presence of repeated bending stress to one point of the lead wire Bend radius Tensile force to lead wire Correct wiring Correct tensile force increase bend ...

Страница 20: ...ternal voltage drop 0 8 V or less at 10 mA load current 2 V or less at 40 mA load current 4 V or less Leakage current 100 A or less at 24 VDC 0 8 mA or less Operating time 1 ms or less Indicator light Operation range red LED Electrical entry type Grommet Lead wire Oilproof heavy duty vinyl cord 2 7 x 3 2 oval 0 15 mm2 2 wire D F6B 3 wire D F6N D F6P Insulation resistance 50 M or more under the tes...

Страница 21: ... 20 No D S OMI0002 B Dimensions ...

Страница 22: ...eter Series Section 20 25 32 40 50 63 HYQ Operating range 8 7 5 9 8 5 8 5 9 HYC Operating range 9 8 5 9 9 HYG Operating range 8 7 5 9 8 5 8 5 9 It is not for guarantee but measure including hysteresis Dispersion is approx 50 It might be changed drastically depending on the ambient ...

Страница 23: ...vision history A Special tools were added page 13 B Revision Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2004 2012 SMC Corporation All Rights Reserved ...

Отзывы: