-18-
No.D-
※
S-OMI0002-B
Reference
No.
Problem
Possible cause
Investigation method
Countermeasure
Not match with
load specification
(2-wire type)
Check if load specification
satisfy the formula below.
Load ON voltage
< Load voltage –
(Switch internal voltage drop
x n)
n: Number of switch connected
in serial
Change to 3-wire type.
Reduce the number of switch
connected in serial.
Wiring failure
(Output line)
(3-wire type)
Connect condition
(connector contact pin / crimp
terminal).
Correct wiring.
(Re-wiring the connecting part)
5
Output stays
OFF
Display is
normal
Disconnection of
lead wire (black)
(3-wire type)
Presence of repeated bending
stress to one point of the lead
wire.
(Bend radius / Tensile force to
lead wire)
Correct wiring.
(Correct tensile force / increase
bend radius)
Incorrect setting
(mounting) position
Check if detection is made
around the limit of operation
range.
Correct the position.
(center of the operation range).
Set position
displacement
Loose set bracket or set screw.
Fix at the right position with right
torque.
Tightening torque: 0.8 to 1.4 Nm
Wiring failure
Condition of connecting part
(connector contact pin / crimp
terminal).
Correct wiring.
(Re-wiring of connecting part)
Lead wire
disconnection
Presence of repeated bending
stress to one point of the lead
wire.
(Bend radius / Tensile force to
lead wire)
Correct wiring.
(Correct tensile force / increase
bend radius)
Unstable
operation
(Chattering)
Malfunction due
to turbulence
magnetic field
Presence of magnetic field
generating source around the
cylinder.
(Cylinder, electric welding
machine conductor, motor,
magnet etc.)
Use the shield between
magnetic field generating source
and cylinder.
Keep the cylinder away from
magnetic field generating
source.
Multiple point
operation
Malfunction due to
turbulence
magnetic field
Influence of the magnetic field of
adjacent cylinder.
Use magnetic shield between
Cylinders.
6
Load does not
operate
Detect the
intermediate
position of the
stroke
Check if piston speed satisfy the
formula below.
Load operation time [s]
< Switch operation time [mm] /
piston speed [mm/s]
Reduce the piston speed until
the formula is satisfied