Mounting

Caution

1. Take care to avoid striking the cylinder tube with 

other objects or handling it in a way that could 
cause deformation.

The cylinder tube and slider units have a non-contact 
construction. For this reason, even a slight deformation or 
slippage of position can cause malfunction and loss of 
durability, as well as a danger of degrading the particulate 
generation characteristics.

2. Do not scratch or gouge the linear guide by striking 

it with other objects.

Since the linear guide is specially treated for maximum 
suppression of particulate generation due to sliding, even a 
slight scratch can cause malfunction and loss of durability, as 
well as a danger of degrading the particulate generation 
characteristics.

3. Since the slide table is supported by precision 

bearings, do not apply strong impacts or excessive 
moment when mounting workpieces.

The slide table may contact with the cylinder tube.

4. Be sure to operate the cylinder with the plates on 

both sides secured.

Avoid applications in which the slide table or only one plate is 
secured.

5. When changing the ports to be used, be sure that 

unused ports are securely sealed.

Take sufficient care in sealing unused ports, because if ports 
are not properly sealed air can leak from the ports and 
particulate generation  characteristics can be degraded.

6. Do not loosen the bolts that fix the block of the 

linear guide and slide table.

The slide table may contact with the cylinder tube.

7. It is recommended to place the load's center of 

gravity on the cylinder linear guide.

The linear guide position is off-set from the cylinder center 
axis, so it is recommended to place the load’s center of gravity 
on the linear guide.

Handling

Caution

1. Open the inner package of the double packaged 

clean series inside a clean room or other clean 
environment.

2. Perform parts replacement and disassembly work in 

a clean room after exhausting compressed air in the 
piping outside the clean room.

Operation

Caution

1. The maximum operating pressure for the clean 

rodless cylinder is 0.3 MPa. 

If the maximum operating pressure of 0.3 MPa for the clean 
rodless cylinder is exceeded, the magnetic coupling can be 
broken, causing a danger of malfunction or degradation of 
particulate generation characteristics, etc.

2. The product can be used with a direct load applied 

within the allowable range, but careful alignment is 
necessary when connecting to a load having an 
external guide mechanism.

Since alignment variations increase as the stroke gets longer, 
use a connection method which can absorb these variations 
and consider measures to control particulate generation.

3. 

When used for vertical operation, use caution 
regarding possible dropping due to separation of 
the magnetic coupling.

When used for vertical operation, use caution as there is a 
possibility of dropping due to separation of the magnetic 
coupling if a load (pressure) greater than the allowable value is 
applied.

4. Do not operate with the magnetic coupling out of 

position.

If the magnetic coupling is out of position, push the external 
slider by hand (or the piston slider with air pressure) back to 
the proper position at the stroke end.

5. Do not supply lubrication, as this is a non-lube 

product.

The interior of the cylinder is lubricated at the factory, and 
lubrication with turbine oil, etc., will not satisfy the product's 
specifications.

Series 

CYP

Specific Product Precautions 1

Be sure to read before handing.
Refer to front matters 54 and 55 for Safety Instructions and pages 3 to 11 for Actuator 
and Auto Switch Precautions.

1260

P1165-P1262-E.qxd  08.10.3 2:34 PM  Page 1260

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Содержание CYP Series

Страница 1: ...CY1F CYP CY3B CY3R Individual X D X Technical data P1165 P1262 E qxd 08 10 3 2 34 PM Page 1249 Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Office 650 588 920...

Страница 2: ...les Cylinder CYP32 200 Workpiece weight 5 kg Average speed 200 mm s Note 5 The data above provide a guide for selection but is not guaranteed Piping port positions can be selected to accommodate the i...

Страница 3: ...the stroke end We 5 x 10 3 x m x g x U Average load coefficient Me1 Moment Moment generated by the workpiece weight even when the cylinder is stopped N m Model CYP15 CYP32 A 16 5 27 0 B 25 5 48 0 Sta...

Страница 4: ...We L2 A 10 3 1 3 14 7 50 27 10 3 0 38 N m 3 Me3 Me3 max 0 38 3 0 13 Me1 1 3 We L1 B 10 3 1 3 14 7 50 48 10 3 0 48 N m 4 Me1 Me1 max 0 48 3 0 16 n 1 2 3 4 0 20 0 24 0 13 0 16 0 73 n 0 73 1 Therefore it...

Страница 5: ...operating pressure to no more than 0 3 MPa Table deflection due to pitch moment load Table deflection due to yaw moment load Table deflection due to roll moment load Moment N m Moment N m Moment N m M...

Страница 6: ...o switch model Electrical entry direction Relay PLC Relay PLC 5 Z Clean Rodless Cylinder Series CYP 15 32 How to Order 15 32 15 mm 32 mm Bore size Standard stroke 15 32 100 150 200 250 300 350 400 450...

Страница 7: ...since it may vary Note 2 The piston speed above indicates the maximum speed It takes approx 0 5 seconds for a single side and approx 1 second for both sides for a sliding table to move through the cu...

Страница 8: ...terial Note Cylinder tube gasket O ring O ring Steel ball Bumper Hexagon socket head set screw Hexagon socket head cap screw Round head Phillips screw Hexagon socket head plug Linear guide Hexagon soc...

Страница 9: ...oduct Precautions Cushion Effect Sine Cushion and Stroke Adjustment on page 1261 CYP15 CYP32 A 8 12 B 9 5 14 E 4H9 6H9 ED 9 5 13 EK 4 6 F 12 5 25 G 6 5 8 5 H 45 75 HA 19 5 39 HB 8 5 19 HG 8 5 19 HI 23...

Страница 10: ...tion D Z7 D Z80 D Y7 W D Y7 WV D Y5 D Y6 D Y7P D Y7PV D Y7 W D Y7 WV D Z7 D Z80 When mounting auto switches they should be inserted into the cylinder s auto switch installation groove from the directi...

Страница 11: ...n room or other clean environment 2 Perform parts replacement and disassembly work in a clean room after exhausting compressed air in the piping outside the clean room Operation Caution 1 The maximum...

Страница 12: ...to be used Speed adjustment can also be performed with a meter in or meter out type speed controller for clean room use but it may not be possible to obtain smooth starting and stopping operation 2 I...

Страница 13: ...upper reliability limit value for time series data up to 500 thousand operation cycles Cylinder CYP32 200 Workpiece weight 5 kg Average speed 200 mm s Note 5 The data above provides a guide for selec...

Отзывы: