前付 7
Precautions when Converting Rotational Motion to Linear Motion
When using a link mechanism, etc., to convert rotational motion to linear motion, and determining the operation
end using the stopper on the linear motion end (see below), a small value for θ at the operation end may result in
the torque of the rotary actuator causing excessive radial load to act on the output axle, and equipment breakage
may occur.
Install a stopper on the rotation motion side, or increase the value of θ at the operation end, to make sure the load
generated does not exceed the allowable value for the product.
(11) Do not use springs, etc., to add force in the rotational movement direction.
When rotational force from an external spring, etc., acts and generates negative pressure on the product’s
interior, breakage of the internal seal or acceleration of abrasion may occur.
(1)
Do not use organic solvent to wipe the area of the name plate that shows the model.
It will erase what is indicated on the name plate.
(2)
Do not hit the output shaft by securing the body or hit the body by securing the output shaft.
These actions could cause the table to bend or damage the bearing. When a load must be coupled to the output
shaft, secure the output shaft.
(3)
Do not step directly onto the table or on the equipment that is coupled to the table.
Standing directly on the output shaft could cause the output shaft or the bearing to become damaged.
(4)
If a product is equipped with an angle adjustment function, use it within the specified adjustment range.
If the product is used outside the specified adjustment range, it could lead to equipment malfunction or product
damage. Refer to the product specifications for details on the adjustment range of the products.
ストッパ
Rotary table
Stopper
Caution