12
Operating environment
Do not use in environments where there is a danger of corrosion.
Refer to "Internal Construction and Components" on pages 4 to 6 for materials used for
the rotary actuator.
Never use this product in dusty locations or where water, oil, etc., splash on the equipment.
Air Supply
(1)
The air supplied to the rotary actuator shall be filtered by an SMC air filter and regulated
to the specified set pressure by an SMC AR series regulator.
(2)
This is a non-lube type actuator. Never supply lubricant oil.
(3)
If lubricant is supplied to the actuator, the grease inside the actuator will be washed away,
and this may cause operation failure.
Compressed air containing a large amount of condensate may cause malfunction of
rotary actuator.
Therefore, take appropriate measures to ensure air quality, such as by providing an after cooler,
air dryer, or water separator.
Warning
Caution